Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1596) (remove)
Document Type
- Article (1596) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- CellDrum (3)
- Label-free detection (3)
- biosensors (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- shakedown analysis (3)
Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself.
Methods: A total of 12 young 25.5-year-old (24.0–28.8) [median(1st quartile–3rd quartile)] and 12 senior 68.5-year-old (63.8–71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8–65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5–35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated.
Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280–500] RU/s) and in validated healthy seniors (400 [320–510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains.
Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.
Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.
Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors
(2012)
Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.
Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt.
All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.
Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.
Diese Studie beschäftigte sich mit der Dämpfungswirkung von Schienbeinschonern, wie sie beim Fußball zum Einsatz kommen. Sie wurde mit Hilfe eines Pendelhammers durchgeführt, der verschiedene Aufschlagkräfte auf die Schoner ermöglichte. Dabei wurde deutlich, dass Schienbeinschoner die beste Wirkung bei Maximalkräften unterhalb von 5kN erreichen können, dass bei größerer Belastung allerdings Verbesserungsbedarf besteht. Hierfür konnte, u.a. durch den Einsatz neuer Materialien, ein guter Ansatzpunkt im „adäquaten Zusammenspiel von Schale und Polsterung“ der Schoner gefunden werden. Die Untersuchung hat weiterhin gezeigt, dass zumindest teilweise eine deutliche Verbesserung der Dämpfungswirkung der Schienbeinschoner in den letzten Jahren erreicht werden konnte.