Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1546)
- Fachbereich Wirtschaftswissenschaften (700)
- Fachbereich Elektrotechnik und Informationstechnik (629)
- Fachbereich Energietechnik (598)
- Fachbereich Chemie und Biotechnologie (589)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (472)
- IfB - Institut für Bioengineering (428)
- Fachbereich Luft- und Raumfahrttechnik (368)
- Fachbereich Bauingenieurwesen (327)
Has Fulltext
- no (5531) (remove)
Language
Document Type
- Article (5531) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- SLM (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
Bald eine Dekade ist es her, dass diese annähernd mantraartig wiederholte Phrase Unternehmen zur Umsetzung datenschutzrechtlicher Vorgaben incentivierte. Was ist davon geblieben? Nur wenige in Deutschland verhängte Bußgelder erreichten Millionenhöhe. Hintergrund ist (auch) das deutsche Ordnungswidrigkeitenrecht, welches in einem Spannungsverhältnis zu den Vorgaben der DS-GVO steht. Ein Bußgeldbescheid der Berliner Datenschutzaufsicht gegen die Deutsche Wohnen sollte Auslöser eines langen, fortdauernden Rechtsstreits werden. Auf Vorlage des KG hatte der EuGH in der Rechtssache C-807/21 („Deutsche Wohnen“) erstmals Gelegenheit, sich zur Frage der Bußgeldhaftung zu positionieren.
Seit Ende 2022 prägt das Schlagwort „Künstliche Intelligenz“ (KI) nicht nur den rechtswissenschaftlichen Diskurs. Die allgemeine Verfügbarkeit von generativen KI-Modellen, allen voran die großen Sprachmodelle (Large Language Models, kurz: LLM) wie ChatGPT von OpenAI oder Bing AI von Microsoft, erfreuen sich größter Beliebtheit: LLM sind in der Lage, auf Grundlage statistischer Methoden – eine entsprechende Schnittstelle (Interface) vorausgesetzt – auch technisch wenig versierten Nutzern verständliche Antworten auf ihre Fragen zu liefern. Dabei werden nicht nur umfassend Nutzerdaten verarbeitet, sondern auch auf weitere personenbezogene Daten zugegriffen sowie neue Daten erzeugt. Der Beitrag geht der Frage nach, welche spezifischen datenschutzrechtlichen Herausforderungen sich für Unternehmen beim Einsatz solcher LLM stellen.
Das Thema Datenschutz wurde bei der öffentlichen Auftragsvergabe bislang vor allem in Bezug auf Drittlandtransfers personenbezogener Daten in die USA diskutiert. Jedoch spielt der Datenschutz für das Vergabeverfahren und für die Ausführung datenschutzrelevanter Leistungen generell eine wesentliche Rolle. Gleichwohl herrschen bislang unter öffentlichen Auftraggebern Schwierigkeiten, datenschutzrechtlich relevante Fallkonstellationen zu erkennen, die möglichen Risiken daraus abzuleiten und, sofern dies gelingt, diesen Risiken angemessen zu begegnen. Der vorliegende Beitrag befasst sich mit der datenschutzrechtlichen Verantwortlichkeit, ihren Folgen und den daraus resultierenden Konsequenzen für die Gestaltung von Vergabeverfahren und Vergabeunterlagen.
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.
Magnetic Resonance Imaging (MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device (ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure- or motion borne sounds.
Wer A sagt, muss zumindest im Kaufrecht nicht immer B sagen: Es kommt nicht selten vor, dass sich in einem Kaufvertrag einerseits ein wirksamer Ausschluss der Gewährleistung des Verkäufers für Sachmängel findet, die Parteien aber andererseits gleichwohl eine Beschaffenheitsvereinbarung für bestimmte Eigenschaften vertraglich festlegen. In diesem Problemfeld führt eine aktuelle Entscheidung des BGH zu weiteren Klärungen für die Praxis (BGH, Urt. v. 10.4.2024 – VIII ZR 161/23, MDR 2024, 706). Der folgende Beitrag setzt sich mit den vielfältigen Aspekten der Entscheidung auseinander und erläutert, aus welchen Gründen der BGH dem Käufer einige goldene Brücken für einen Schadensersatzanspruch gebaut hat.
This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered.
The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques.
The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx.
Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance.
The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders.