Refine
Year of publication
- 2016 (284) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- Fachbereich Chemie und Biotechnologie (44)
- Fachbereich Bauingenieurwesen (35)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- IfB - Institut für Bioengineering (35)
- Fachbereich Wirtschaftswissenschaften (31)
- Fachbereich Luft- und Raumfahrttechnik (28)
- Fachbereich Maschinenbau und Mechatronik (26)
- Fachbereich Energietechnik (17)
- INB - Institut für Nano- und Biotechnologien (15)
Document Type
- Article (118)
- Conference Proceeding (81)
- Part of a Book (29)
- Book (25)
- Other (10)
- Conference: Meeting Abstract (8)
- Report (6)
- Doctoral Thesis (3)
- Part of a Periodical (2)
- Patent (1)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Archeology (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
Schienenverkehrssysteme stehen in zunehmendem Wettbewerb, sowohl untereinander als auch mit anderen Verkehrsträgern. Als wichtiger Aspekt zur Steigerung der Kosteneffizienz wird die Digitalisierung des Betriebs und der Fahrzeuge betrachtet. Über eine Prognose der Ausfallwahrscheinlichkeit bzw. Restlebensdauer von Subsystemen können mittels Digitalisierung die Instandhaltungskosten gesenkt werden. Die geringen Fehlerraten im System Bahn machen die Nutzung besonderer Simulationstechniken notwendig. In diesem Beitrag wird gezeigt, wie sich die Subsystemverfügbarkeit aus den beobachteten Fehlerraten der Teilfunktionen vorhersagen lässt.
This work presents a methodology for automated
damage-sensitive feature extraction and anomaly
detection under multivariate operational variability
for in-flight assessment of wings. The
method uses a passive excitation approach, i. e.
without the need for artificial actuation. The
modal system properties (natural frequencies and
damping ratios) are used as damage-sensitive
features. Special emphasis is placed on the use
of Fiber Bragg Grating (FBG) sensing technology
and the consideration of Operational and
Environmental Variability (OEV). Measurements
from a wind tunnel investigation with a composite
cantilever equipped with FBG and piezoelectric
sensors are used to successfully detect an impact
damage. In addition, the feasibility of damage
localisation and severity estimation is evaluated
based on the coupling found between damageand
OEV-induced feature changes.
The main objective of the BATIMASS project was to address how the energy balance in relatively lightweight steel buildings can be improved by building in ‘active thermal mass’ (ATM) into the building fabric. This was achieved through concept design, dynamic thermal modelling and testing of a number of potentially viable systems and concepts. A significant programme of thermal simulation modelling was undertaken utilising the thermally equivalent slab (TES) concept to model the passive thermal capacity effect of profiled, composite metal floor decks. It is apparent from the modelling results that thermal mass is a highly complex phenomenon which is highly dependent upon building type, occupancy patterns, climate and many other aspects of the building design and servicing strategy. The ATM systems developed, both conceptually and for prototype testing, focussed on water-cooled composite slabs, the Cofradal floor system and the phase change material (PCM) Energain. In addition to laboratory testing of prototypes, whole building monitoring was undertaken at the Kubik building in Spain and the RWTH test building in Germany. Advanced thermal modelling was also undertaken to estimate the likely benefits of the ATM concept designs developed and for comparison with the test results. In addition to thermal testing, structural tests were conducted on composite floor specimens incorporating embedded water pipes. This Final Report presents the results of the activities carried out under this RFCS contract RFSR CT 2012 00033. The work carried out is reported in six major sections corresponding to the technical Work Packages of the project. Only summaries of the work carried out are provided in this report; all work undertaken is fully reported in the formal project deliverables.
Purpose
To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously.
Methods
A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used.
Results
Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity.
Conclusion
It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times.
Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance.
Objective
This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation.
Materials and methods
The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading.
Results
Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T.
Conclusion