Conference Proceeding
Refine
Year of publication
- 2006 (94) (remove)
Document Type
- Conference Proceeding (94) (remove)
Keywords
- Biosensor (23)
- Bauingenieurwesen (2)
- Bauplanung (2)
- CAD (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Absolvententreffen (1)
- Abwasser (1)
- Alfha.net (1)
- Alumni (1)
- Anlagenwirtschaft (1)
- Asteroid Deflection (1)
- BTEX compounds (1)
- Bauführung (1)
- Bauherrenvertretung (1)
- Bauleitung (1)
- Baurevision (1)
- Berufsperspektiven (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (34)
- Fachbereich Bauingenieurwesen (15)
- Fachbereich Maschinenbau und Mechatronik (14)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Energietechnik (10)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Wirtschaftswissenschaften (5)
- Solar-Institut Jülich (4)
- IfB - Institut für Bioengineering (3)
- Nowum-Energy (2)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Chemie und Biotechnologie (1)
- Fachbereich Elektrotechnik und Informationstechnik (1)
- Fachbereich Gestaltung (1)
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.