Conference Proceeding
Refine
Year of publication
- 2009 (22) (remove)
Document Type
- Conference Proceeding (22) (remove)
Has Fulltext
- yes (22) (remove)
Keywords
- Blitzschutz (3)
- Fließgewässer (3)
- Geodatenbank (3)
- Geodatenhaltung (3)
- Geoinformationen (3)
- Geoinformationssystem (3)
- Renaturierung <Ökologie> (2)
- Stickstoffmonoxid (2)
- Wasserwirtschaft (2)
- nitric oxide gas (2)
- Aachen / Fachhochschule Aachen ; Graduierter ; Promotionsstudium (1)
- Adsorption (1)
- Autofluoreszenzverfahren (1)
- Biophoton (1)
- Biosensor (1)
- Blitzeinschlag (1)
- Braunkohlenbergbau (1)
- Breitband Markt (1)
- Bundesnetzagentur (1)
- Eisschicht (1)
Institute
Dr.-Ing. Oliver Stoschek [u.a.] DHI Wasser und Umwelt GmbH, Syke. 14 S. (S. 45-58). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Ökologische Modelle zur Berechnung der Temperaturveränderung und den Einfluss von Kühlwasser auf die Wassertemperatur der Elbe. Die vorgelegte Arbeit wurde beauftragt und unterstützt von der ARGE Elbe im Zuge der Neuauflage des Wärmelastplans Elbe.
One of interesting but not well known water properties is related to appearance of highly ordered structures in response to strong electrical field. In 1893 Sir William Armstrong placed a cotton thread between two wine glasses filled with chemically pure water. When high DC voltage was applied between the glasses, a connection consisting of water formed, producing a "water bridge"
8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen.
In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.
The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS).
Mischwassereinleitungen in Gewässer nach BWK Merkblatt M3 - Vorteile des detaillierten Nachweises
(2009)
Dipl.-Ing. Brigitte Huber und Dr.-Ing. Gerd Demny - Wasserverband Eifel Rur, Düren. 16 Seiten ( S. 59-74). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Zusammenfassung [der Autoren] Für das städtisch geprägte Einzugsgebiet des Broicher Baches sind ein vereinfachter und ein detaillierter Nachweis nach BWK-M3 durchgeführt worden. Dabei zeigt sich, dass die Methodik des vereinfachten Nachweises nicht geeignet ist, um eine realitätsnahe Abbildung der einleitungsgeprägten Abflüsse des Gewässers zu erhalten. Dies ist insbesondere auf die Vernachlässigung von Wellentranslation und -retention im Gerinne zurückzuführen. Die dadurch entstehende Fehleinschätzung der Abflussverhältnisse versperrt den Blick auf eine situationsgerechte Maßnahmenplanung. Der mit Hilfe eines NA-Modells geführte detaillierte Nachweis ist zwar in der Erstellung aufwändiger, zeichnet aber ein reales Bild der Abflusserhöhung durch Einleitungen. Mit Hilfe des Modells können die wesentlichen Einflüsse schnell lokalisiert und zielführende Maßnahmenvarianten identifiziert werden. In dem hier vorgestellten Beispiel des Broicher Baches können die ursprünglich identifizierten acht Maßnahmen auf eine reduziert werden. Das Gesamtvolumen der erforderlichen Rückhaltungen wird um die Hälfte verringert. Der Vergleich beider Nachweismethoden legt nach Ansicht der Autoren nahe, den vereinfachten Nachweis höchstens für eine erste Einschätzung des Maßnahmenbedarfs anzuwenden. Die Maßnahmenidentifikation und -dimensionierung sollte grundsätzlich mit der detaillierten Nachweismethode durchgeführt werden, die auf einem entsprechenden NA-Modell basiert. Dies gilt insbesondere für Gewässerstrecken, deren Abfluss durch mehrere, hintereinander liegende Einleitungsstellen geprägt ist.
Dipl.-Ing. Stefan Overkamp - GISWORKS GbR, Velbert. 11 S. (S. 7-17). Beitrag zum 2. Aachener Softwaretag in der Wasserwirtschaft <2, 2009, Aachen> Aus der Gliederung: 1 Geoinformationssysteme 2 Anforderungen an eine kommunale Geodateninfrastruktur (GDI) 3 Komponenten einer GDI 3.1 Geodatenmanagement 3.2 Geodatenhaltung 3.3 High-End-GIS 3.4 intraGIS 4 GISWORKS 5 Weiterführende Informationen