Refine
Year of publication
- 2024 (3)
- 2023 (10)
- 2022 (16)
- 2021 (8)
- 2020 (9)
- 2019 (11)
- 2018 (18)
- 2017 (12)
- 2016 (29)
- 2015 (22)
- 2014 (25)
- 2013 (26)
- 2012 (15)
- 2011 (22)
- 2010 (15)
- 2009 (16)
- 2008 (9)
- 2007 (14)
- 2006 (12)
- 2005 (10)
- 2004 (8)
- 2003 (7)
- 2002 (13)
- 2001 (12)
- 2000 (8)
- 1999 (11)
- 1998 (19)
- 1997 (13)
- 1996 (7)
- 1995 (19)
- 1994 (18)
- 1993 (5)
- 1992 (17)
- 1991 (5)
- 1990 (9)
- 1989 (12)
- 1988 (13)
- 1987 (8)
- 1986 (5)
- 1985 (6)
- 1984 (6)
- 1983 (4)
- 1982 (3)
- 1981 (1)
- 1980 (2)
- 1979 (1)
- 1978 (2)
- 1973 (1)
- 1971 (1)
Institute
- Fachbereich Chemie und Biotechnologie (538) (remove)
Has Fulltext
- no (538) (remove)
Language
- English (538) (remove)
Document Type
- Article (459)
- Conference Proceeding (24)
- Part of a Book (18)
- Patent (17)
- Book (9)
- Conference: Meeting Abstract (8)
- Conference Poster (1)
- Preprint (1)
- Review (1)
Keywords
- Heparin (3)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- ABE (1)
- Acid crash (1)
Opioid Analgesia in P450 Gene Cluster Knockout Mice: A Search for Analgesia-Relevant Isoforms
(2015)
Optical Fibers as Dosimeter Detectors for Mixed Proton/Neutron Fields - A Biological Dosimeter
(2023)
In recent years, proton therapy has gained importance as a cancer treatment modality due to its conformality with the tumor and the sparing of healthy tissue. However, in the interaction of the protons with the beam line elements and patient tissues, potentially harmful secondary neutrons are always generated. To ensure that this neutron dose is as low as possible, treatment plans could be created to also account for and minimize the neutron dose. To monitor such a treatment plan, a compact, easy to use, and inexpensive dosimeter must be developed that not only measures the physical dose, but which can also distinguish between proton and neutron contributions. To that end, plastic optical fibers with scintillation materials (Gd₂O₂S:Tb, Gd₂O₂S:Eu, and YVO₄:Eu) were irradiated with protons and neutrons. It was confirmed that sensors with different scintillation materials have different sensitivities to protons and neutrons. A combination of these three scintillators can be used to build a detector array to create a biological dosimeter.
The optical study carried out on insulating polymers namely polyethyleneterephthalate (PET) and polyvinylchloride (PVC) has been described. The polymers are exposed to different radiation doses by exposing them to swift heavy ions of carbon (90 MeV), silicon (120 MeV) and nickel (100 MeV) which influence on their optical properties. The studies show that amongst the investigated polymers, PVC and PET have potential for application as dosimeter beyond a threshold dose which is strongly dependent on the nature of the material and the radiation type. The optical micrographs show a distinct change in colour of the sample with increase in radiation dose.
Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.