Conference Proceeding
Refine
Year of publication
- 2024 (14)
- 2023 (37)
- 2022 (48)
- 2021 (52)
- 2020 (55)
- 2019 (93)
- 2018 (74)
- 2017 (86)
- 2016 (72)
- 2015 (78)
- 2014 (55)
- 2013 (74)
- 2012 (81)
- 2011 (70)
- 2010 (68)
- 2009 (64)
- 2008 (48)
- 2007 (44)
- 2006 (53)
- 2005 (29)
- 2004 (25)
- 2003 (22)
- 2002 (25)
- 2001 (18)
- 2000 (14)
- 1999 (15)
- 1998 (21)
- 1997 (10)
- 1996 (7)
- 1995 (6)
- 1994 (4)
- 1993 (11)
- 1992 (6)
- 1991 (3)
- 1990 (2)
- 1989 (5)
- 1988 (3)
- 1987 (1)
- 1986 (2)
- 1985 (4)
- 1984 (3)
- 1983 (3)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1977 (2)
- 1975 (3)
- 1974 (1)
- 1973 (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (286)
- Fachbereich Energietechnik (226)
- Fachbereich Luft- und Raumfahrttechnik (198)
- Fachbereich Maschinenbau und Mechatronik (190)
- Solar-Institut Jülich (164)
- Fachbereich Medizintechnik und Technomathematik (152)
- IfB - Institut für Bioengineering (114)
- Fachbereich Bauingenieurwesen (103)
- ECSM European Center for Sustainable Mobility (62)
- Fachbereich Wirtschaftswissenschaften (55)
Has Fulltext
- no (1421) (remove)
Document Type
- Conference Proceeding (1421) (remove)
Keywords
- Enterprise Architecture (5)
- Gamification (5)
- Energy storage (4)
- Natural language processing (4)
- Power plants (4)
- hydrogen (4)
- solar sail (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
The major advantage of labyrinth weirs over linear weirs is hydraulic efficiency. In hydraulic modeling efforts, this strength contrasts with limited pump capacity as well as limited computational power for CFD simulations. For the latter, reducing the number of investigated cycles can significantly reduce necessary computational time. In this study, a labyrinth weir with different cycle numbers was investigated. The simulations were conducted in FLOW-3D HYDRO as a Large Eddy Simulation. With a mean deviation of 1.75 % between simulated discharge coefficients and literature design equations, a reasonable agreement was found. For downstream conditions, overall consistent results were observed as well. However, the orientation of labyrinth weirs with a single cycle should be chosen carefully under consideration of the individual research purpose.
Reinforced concrete frames with masonry infill walls are popular form of construction all over the world as well in seismic regions. While severe earthquakes can cause high level of damage of both reinforced concrete and masonry infills, earthquakes of lower to medium intensity some-times can cause significant level of damage of masonry infill walls. Especially important is the level of damage of face loaded infill masonry walls (out-of-plane direction) as out-of-plane load cannot only bring high level of damage to the wall, it can also be life-threating for the people near the wall. The response in out-of-plane direction directly depends on the prior in-plane damage, as previous investigation shown that it decreases resistance capacity of the in-fills. Behaviour of infill masonry walls with and without prior in-plane load is investigated in the experimental campaign and the results are presented in this paper. These results are later compared with analytical approaches for the out-of-plane resistance from the literature. Conclusions based on the experimental campaign on the influence of prior in-plane damage on the out-of-plane response of infill walls are compared with the conclusions from other authors who investigated the same problematic.