Refine
Year of publication
- 2024 (47)
- 2023 (167)
- 2022 (219)
- 2021 (218)
- 2020 (218)
- 2019 (300)
- 2018 (248)
- 2017 (254)
- 2016 (251)
- 2015 (284)
- 2014 (265)
- 2013 (283)
- 2012 (291)
- 2011 (305)
- 2010 (317)
- 2009 (332)
- 2008 (289)
- 2007 (271)
- 2006 (276)
- 2005 (263)
- 2004 (286)
- 2003 (218)
- 2002 (232)
- 2001 (210)
- 2000 (234)
- 1999 (232)
- 1998 (236)
- 1997 (214)
- 1996 (200)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (110)
- 1988 (103)
- 1987 (105)
- 1986 (81)
- 1985 (83)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
Document Type
- Article (5464)
- Conference Proceeding (1393)
- Book (1056)
- Part of a Book (544)
- Patent (172)
- Bachelor Thesis (156)
- Report (81)
- Doctoral Thesis (78)
- Other (68)
- Contribution to a Periodical (19)
- Master's Thesis (17)
- Review (17)
- Working Paper (8)
- Talk (5)
- Habilitation (4)
- Preprint (4)
- Diploma Thesis (3)
- Poster (3)
- Part of Periodical (2)
- Examination Thesis (1)
Language
Has Fulltext
- no (9096) (remove)
Keywords
- Corporate Design (9)
- Illustration (9)
- Erscheinungsbild (8)
- Gamification (8)
- Nachhaltigkeit (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Digitalisierung (6)
- avalanche (6)
- App (5)
- Earthquake (5)
- Editorial (5)
- Enterprise Architecture (5)
- Fotografie (5)
- Geschichte (5)
- MINLP (5)
- solar sail (5)
- Aktionskunst (4)
- Design (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1907)
- Fachbereich Elektrotechnik und Informationstechnik (1116)
- Fachbereich Wirtschaftswissenschaften (1100)
- Fachbereich Energietechnik (1056)
- Fachbereich Chemie und Biotechnologie (829)
- Fachbereich Maschinenbau und Mechatronik (799)
- Fachbereich Luft- und Raumfahrttechnik (749)
- Fachbereich Bauingenieurwesen (658)
- IfB - Institut für Bioengineering (623)
- INB - Institut für Nano- und Biotechnologien (584)
- Solar-Institut Jülich (334)
- Fachbereich Gestaltung (333)
- Fachbereich Architektur (161)
- ECSM European Center for Sustainable Mobility (106)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (66)
- Nowum-Energy (64)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (62)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (21)
Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at −21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at −21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media.
New information regarding the influence of a stepped chute on the hydraulic performance of the United States Bureau of Reclamation (Reclamation) Type III hydraulic jump stilling basin is presented for design (steady) and adverse (decreasing tailwater) conditions. Using published experimental data and computational fluid dynamics (CFD) models, this paper presents a detailed comparison between smooth-chute and stepped-chute configurations for chute slopes of 0.8H:1V and 4H:1V and Froude numbers (F) ranging from 3.1 to 9.5 for a Type III basin designed for F = 8. For both stepped and smooth chutes, the relative role of each basin element was quantified, up to the most hydraulic extreme case of jump sweep-out. It was found that, relative to a smooth chute, the turbulence generated by a stepped chute causes a higher maximum velocity decay within the stilling basin, which represents an enhancement of the Type III basin’s performance but also a change in the relative role of the basin elements. Results provide insight into the ability of the CFD models [unsteady Reynolds-averaged Navier-Stokes (RANS) equations with renormalization group (RNG) k-ϵ turbulence model and volume-of-fluid (VOF) for free surface tracking] to predict the transient basin flow structure and velocity profiles. Type III basins can perform adequately with a stepped chute despite the effects steps have on the relative role of each basin element. It is concluded that the classic Type III basin design, based upon methodology by reclamation specific to smooth chutes, can be hydraulically improved for the case of stepped chutes for design and adverse flow conditions using the information presented herein.
Vectrino profiler spatial filtering for shear flows based on the mean velocity gradient equation
(2018)
A new methodology is proposed to spatially filter acoustic Doppler velocimetry data from a Vectrino profiler based on the differential mean velocity equation. Lower and upper bounds are formulated in terms of physically based flow constraints. Practical implementation is discussed, and its application is tested against data gathered from an open-channel flow over a stepped macroroughness surface. The method has proven to detect outliers occurring all over the distance range sampled by the Vectrino profiler and has shown to remain applicable out of the region of validity of the velocity gradient equation. Finally, a statistical analysis suggests that physically obtained bounds are asymptotically representative.
A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples.
In this study, flexible calorimetric gas sensors are developed for specificdetection of gaseous hydrogen peroxide (H₂O₂) over a wide concentrationrange, which is used in sterilization processes for aseptic packaging industry.The flexibility of these sensors is an advantage for identifying the chemical components of the sterilant on the corners of the food boxes, so-called “coldspots”, as critical locations in aseptic packaging, which are of great importance. These sensors are fabricated on flexible polyimide films by means of thin-film technique. Thin layers of titanium and platinum have been deposited on polyimide to define the conductive structures of the sensors. To detect the high-temperature evaporated H₂O₂, a differential temperature set-up is proposed. The sensors are evaluated in a laboratory-scaled sterilizationsystem to simulate the sterilization process. The concentration range of the evaporated H₂O₂ from 0 to 7.7% v/v was defined and the sensors have successfully detected high as well as low H₂O₂ concentrations with a sensitivity of 5.04 °C/% v/v. The characterizations of the sensors confirm their precise fabrication, high sensitivity and the novelty of low H₂O₂ concentration detections for future inline monitoring of food-package sterilization.