Refine
Year of publication
- 2024 (4)
- 2023 (14)
- 2022 (37)
- 2021 (23)
- 2020 (35)
- 2019 (27)
- 2018 (22)
- 2017 (27)
- 2016 (17)
- 2015 (23)
- 2014 (40)
- 2013 (36)
- 2012 (20)
- 2011 (29)
- 2010 (35)
- 2009 (35)
- 2008 (28)
- 2007 (24)
- 2006 (29)
- 2005 (39)
- 2004 (35)
- 2003 (25)
- 2002 (33)
- 2001 (27)
- 2000 (35)
- 1999 (28)
- 1998 (28)
- 1997 (31)
- 1996 (44)
- 1995 (24)
- 1994 (30)
- 1993 (23)
- 1992 (17)
- 1991 (11)
- 1990 (11)
- 1989 (16)
- 1988 (16)
- 1987 (20)
- 1986 (20)
- 1985 (16)
- 1984 (14)
- 1983 (14)
- 1982 (10)
- 1981 (14)
- 1980 (7)
- 1979 (9)
- 1978 (3)
- 1977 (3)
- 1976 (1)
- 1975 (4)
- 1974 (1)
- 1973 (1)
- 1972 (1)
Institute
- Fachbereich Energietechnik (1116) (remove)
Language
- English (589)
- German (524)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (609)
- Conference Proceeding (259)
- Book (126)
- Part of a Book (84)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
In this paper, we present the structure, the simulation the operation of a multi-stage, hybrid solar desalination system (MSDH), powered by thermal and photovoltaic (PV) (MSDH) energy. The MSDH system consists of a lower basin, eight horizontal stages, a field of four flat thermal collectors with a total area of 8.4 m2, 3 Kw PV panels and solar batteries. During the day the system is heated by thermal energy, and at night by heating resistors, powered by solar batteries. These batteries are charged by the photovoltaic panels during the day. More specifically, during the day and at night, we analyse the temperature of the stages and the production of distilled water according to the solar irradiation intensity and the electric heating power, supplied by the solar batteries. The simulations were carried out in the meteorological conditions of the winter month (February 2020), presenting intensities of irradiance and ambient temperature reaching 824 W/m2 and 23 °C respectively. The results obtained show that during the day the system is heated by the thermal collectors, the temperature of the stages and the quantity of water produced reach 80 °C and 30 Kg respectively. At night, from 6p.m. the system is heated by the electric energy stored in the batteries, the temperature of the stages and the quantity of water produced reach respectively 90 °C and 104 Kg for an electric heating power of 2 Kw. Moreover, when the electric power varies from 1 Kw to 3 Kw the quantity of water produced varies from 92 Kg to 134 Kg. The analysis of these results and their comparison with conventional solar thermal desalination systems shows a clear improvement both in the heating of the stages, by 10%, and in the quantity of water produced by a factor of 3.
Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels.