Refine
Year of publication
- 2024 (4)
- 2023 (14)
- 2022 (37)
- 2021 (23)
- 2020 (35)
- 2019 (27)
- 2018 (22)
- 2017 (27)
- 2016 (17)
- 2015 (23)
- 2014 (40)
- 2013 (36)
- 2012 (20)
- 2011 (29)
- 2010 (35)
- 2009 (35)
- 2008 (28)
- 2007 (24)
- 2006 (29)
- 2005 (39)
- 2004 (35)
- 2003 (25)
- 2002 (33)
- 2001 (27)
- 2000 (35)
- 1999 (28)
- 1998 (28)
- 1997 (31)
- 1996 (44)
- 1995 (24)
- 1994 (30)
- 1993 (23)
- 1992 (17)
- 1991 (11)
- 1990 (11)
- 1989 (16)
- 1988 (16)
- 1987 (20)
- 1986 (20)
- 1985 (16)
- 1984 (14)
- 1983 (14)
- 1982 (10)
- 1981 (14)
- 1980 (7)
- 1979 (9)
- 1978 (3)
- 1977 (3)
- 1976 (1)
- 1975 (4)
- 1974 (1)
- 1973 (1)
- 1972 (1)
Institute
- Fachbereich Energietechnik (1116) (remove)
Language
- English (589)
- German (524)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (609)
- Conference Proceeding (259)
- Book (126)
- Part of a Book (84)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T.