Refine
Year of publication
- 2024 (2)
- 2023 (14)
- 2022 (16)
- 2021 (11)
- 2020 (13)
- 2019 (17)
- 2018 (18)
- 2017 (12)
- 2016 (36)
- 2015 (30)
- 2014 (31)
- 2013 (29)
- 2012 (27)
- 2011 (28)
- 2010 (26)
- 2009 (24)
- 2008 (16)
- 2007 (20)
- 2006 (17)
- 2005 (20)
- 2004 (15)
- 2003 (14)
- 2002 (19)
- 2001 (18)
- 2000 (12)
- 1999 (16)
- 1998 (31)
- 1997 (25)
- 1996 (19)
- 1995 (36)
- 1994 (29)
- 1993 (21)
- 1992 (27)
- 1991 (15)
- 1990 (20)
- 1989 (20)
- 1988 (19)
- 1987 (16)
- 1986 (11)
- 1985 (7)
- 1984 (10)
- 1983 (10)
- 1982 (3)
- 1981 (3)
- 1980 (3)
- 1979 (8)
- 1978 (2)
- 1976 (2)
- 1975 (3)
- 1973 (2)
- 1972 (2)
- 1971 (2)
Document Type
- Article (597)
- Patent (117)
- Book (65)
- Conference Proceeding (34)
- Part of a Book (21)
- Report (5)
- Bachelor Thesis (3)
- Doctoral Thesis (3)
- Diploma Thesis (1)
- Preprint (1)
Language
- English (534)
- German (310)
- Multiple languages (2)
- Spanish (1)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biorefinery (2)
- Biotechnological application (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- Subtilases (2)
- Subtilisin (2)
- bubble column (2)
- methanation (2)
- plug flow reactor (2)
- qNMR (2)
- (Poly)saccharides (1)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alginate beads (1)
- Alkalihalobacillus okhensis (1)
- Aloe vera (1)
- Analytics (1)
- Authenticity (1)
- Bioeconomy (1)
- Bioethanol (1)
- Biofuel (1)
- Biogas (1)
- Biomass (1)
- Biorefinery definitions (1)
- Bladder (1)
- Bragg peak (1)
- Broad pH spectrum (1)
- Butanol (1)
- CRISPR/Cas9 (1)
- Chimeric liver-humanized mice (1)
- Chiralidon-R (1)
- Chiralidon-S (1)
- Chondroitin sulfate (1)
- Circular bioeconomy (1)
- Clostridium acetobutylicum (1)
- Crude heparin (1)
- Cyclotron production (1)
- Decentral (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Dietary supplements (1)
- Drug distribution (1)
- Drug metabolism (1)
- Enzymatic biosensor (1)
- Extracellular enzymes (1)
- Ga-68 (1)
- Glucosamine (1)
- Growth modelling (1)
- Halotolerant protease (1)
- High-field NMR (1)
- Hypersecretion (1)
- IR (1)
- Inorganic ions (1)
- Introduction (1)
- Ions (1)
- Knockout mice (1)
- Levulinic acid (1)
- Lignocellulose (1)
- Lignocellulose feedstook (1)
- Linear discriminant analysis (1)
- Manufacturer (1)
- Marker-free mutagenesis (1)
- Mechanical (1)
- Mechanical simulation (1)
- Medical radionuclide production (1)
- Metal contaminants (1)
- Methane (1)
- Microfluidic solvent extraction (1)
- Minor chemistry (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- NMR (1)
- On-site (1)
- Organic acids (1)
- P2G (1)
- PLS-regression (1)
- Physical chemistry (1)
- Physical chemistry basics (1)
- Physical chemistry starters (1)
- Physikalische Chemie (1)
- Polysaccharides (1)
- Pre-treatment (1)
- Process schemes (1)
- Quality control (1)
- Quantum chemistry (1)
- Reconstruction (1)
- Renewable resources (1)
- Simultaneous determination (1)
- Soft independent modeling of class analogy (1)
- Spectroscopy (1)
- Stenotrophomonas maltophilia (1)
- Streptomyces griseus (1)
- Streptomyces lividans (1)
- Thermodynamics as minor (1)
- Toxicology (1)
- USP (1)
- Uracil-phosphoribosyltransferase (1)
- Ureter (1)
- Wärmeübertragung (1)
- acetoin (1)
- acetoin reductase (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- aspergillus (1)
- bacterial cellulose (1)
- bi-enzyme biosensor (1)
- bio-methane (1)
- bioavailability (1)
- biodegradable polymers (1)
- biological dosimeter (1)
- biomethane (1)
- biosensors (1)
- borehole disposal (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- coculture (1)
- deficit irrigation (1)
- detergent protease (1)
- disposal facility (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- elastomers (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- exopolysaccharides (1)
- filamentous fungi (1)
- genome engineering (1)
- geological disposal (1)
- glycine (1)
- halotolerant protease (1)
- high-alkaline subtilisin (1)
- human metabolites (1)
- hydrogel (1)
- hydrogels (1)
- light-addressable electrode (1)
- light-addressable potentiometric sensor (1)
- mechanical properties (1)
- microfluidics (1)
- micronutrients (1)
- neutrons (1)
- nuclear waste (1)
- onion (1)
- optical fibers (1)
- oxidative stable protease (1)
- penicillinase (1)
- polyaspartic acid (1)
- power-to-gas (1)
- prebiotic (1)
- proton therapy (1)
- protons (1)
- pullulan (1)
- recombinant expression (1)
- relative dosimetry (1)
- retention time (1)
- rubber (1)
- superabsorbent polymers (1)
- supramolecular structures (1)
- swelling properties (1)
- theory and modeling (1)
- tobacco mosaic virus (TMV) (1)
- transporters (1)
- urease (1)
- water economy (1)
- yield (1)
- α-aminoacylase (1)
- ε-lysine acylase (1)
Institute
- Fachbereich Chemie und Biotechnologie (847) (remove)
In the field of biotechnology and molecular biology, the use of small liquid volumes has significant advantages. In particular, screening and optimization runs with acceptable amounts of expensive and hardly available catalysts, reagents, or biomolecules are feasible with microfluidic technologies. The presented new microfluidic system is based on the inclusion of small liquid volumes by a protective shell of magnetizable microparticles. Hereby, discrete aqueous microreactor drops with volumes of 1–30 μL can be formed on a simple planar surface. A digital movement and manipulation of the microreactor is performed by overlapping magnetic forces. The magnetic forces are generated by an electrical coil matrix positioned below a glass plate. With the new platform technology, several discrete reaction compartments can be moved simultaneously on one surface. Due to the magnetic fields, the reactors can even be merged to initiate reactions by mixing or positioned above surface-immobilized catalysts and then opened by magnetic force. Comparative synthesis routes of the magnetizable shell particles and superhydrophobic glass slides including their performance and stability with the reaction platform are described. The influence of diffusive mass transport during the catalyzed reaction is discussed by evaluation finite element model of the microreactor. Furthermore, a first model dye reaction of the enzyme laccase has been established.
Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines flüssigen oder mit Flüssigkeit gefüllten Körpers. Dieser besteht aus einem Träger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0° bis maximal 90° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) für den flüssigen oder mit Flüssigkeit gefüllten Körper. An der Ebene (8) sind mehrere Sensoren (11, 12) zur Erfassung der Rolldauer des Körpers entlang der Rollstrecke angeordnet. Erfindungsgemäß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) über ein Winkelmessgerät (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der Körper in Bewegung gerät. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des Körpers ermittelt.
The invention relates to a system for the implementation of chemical, biological or physical reactions, consisting of - one or more magnetic micro-reactors, each comprising a shell made of hydrophobic magnetic nanoparticles encapsulating an aqueous core, - a plane platform comprising a surface to receive the micro-reactors, - a source that generates a magnetic field above or underneath the platform for manipulating the one or more hydrophobic magnetic micro-reactors, or for moving them along the surface of the platform from one position to another position, characterized in that the aqueous core of the one or more magnetic micro-reactors contains a reaction solution or buffer, and wherein the magnetic field generated by the source correlates to a defined position on the surface of the platform.
Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines flüssigen oder mit Flüssigkeit gefüllten Körpers. Dieser besteht aus einem Träger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0 ° bis maximal 90 ° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) für den flüssigen oder mit Flüssigkeit gefüllten Körper. An der Ebene (8) sind mehrere Sensoren (11,12) zur Erfassung der Rolldauer des Körpers entlang der Rollstrecke angeordnet. Erfindungsgemäß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) über ein Winkelmessgerät (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der Körper in Bewegung gerät. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des Körpers ermittelt.
Mechanical forces/tensile stresses are critical determinants of cellular growth, differentiation and migration patterns in health and disease. The innovative “CellDrum technology” was designed for measuring mechanical tensile stress of cultured cell monolayers/thin tissue constructs routinely. These are cultivated on very thin silicone membranes in the so-called CellDrum. The cell layers adhere firmly to the membrane and thus transmit the cell forces generated. A CellDrum consists of a cylinder which is sealed from below with a 4 μm thick, biocompatible, functionalized silicone membrane. The weight of cell culture medium bulbs the membrane out downwards. Membrane indentation is measured. When cells contract due to drug action, membrane, cells and medium are lifted upwards. The induced indentation changes allow for lateral drug induced mechanical tension quantification of the micro-tissues. With hiPS-induced (human) Cardiomyocytes (CM) the CellDrum opens new perspectives of individualized cardiac drug testing. Here, monolayers of self-beating hiPS-CMs were grown in CellDrums. Rhythmic contractions of the hiPS-cells induce membrane up-and-down deflections. The recorded cycles allow for single beat amplitude, single beat duration, integration of the single beat amplitude over the beat time and frequency analysis. Dose effects of agonists and antagonists acting on Ca2+ channels were sensitively and highly reproducibly observed. Data were consistent with published reference data as far as they were available. The combination of the CellDrum technology with hiPS-Cardiomyocytes offers a fast, facile and precise system for pharmacological and toxicological studies. It allows new preclinical basic as well as applied research in pharmacolgy and toxicology.