Refine
Year of publication
- 2013 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (15)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (5)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2.
Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range.
Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation