Refine
Year of publication
- 2024 (107)
- 2023 (256)
- 2022 (301)
- 2021 (293)
- 2020 (240)
- 2019 (378)
- 2018 (259)
- 2017 (259)
- 2016 (277)
- 2015 (301)
- 2014 (301)
- 2013 (301)
- 2012 (332)
- 2011 (328)
- 2010 (342)
- 2009 (368)
- 2008 (311)
- 2007 (312)
- 2006 (330)
- 2005 (303)
- 2004 (323)
- 2003 (254)
- 2002 (250)
- 2001 (221)
- 2000 (245)
- 1999 (236)
- 1998 (242)
- 1997 (220)
- 1996 (202)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (111)
- 1988 (104)
- 1987 (105)
- 1986 (81)
- 1985 (84)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
- 1925 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2071)
- Fachbereich Elektrotechnik und Informationstechnik (1183)
- Fachbereich Wirtschaftswissenschaften (1158)
- Fachbereich Energietechnik (1114)
- Fachbereich Chemie und Biotechnologie (912)
- Fachbereich Maschinenbau und Mechatronik (867)
- Fachbereich Luft- und Raumfahrttechnik (796)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (615)
Language
- German (5099)
- English (4902)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- Dutch (2)
- Italian (1)
Document Type
- Article (5641)
- Conference Proceeding (1638)
- Book (1079)
- Part of a Book (558)
- Bachelor Thesis (312)
- Patent (174)
- Report (101)
- Doctoral Thesis (79)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (22)
Zugriffsart
- campus (2141)
- weltweit (1857)
- bezahl (761)
- fachbereichsweit (FB4) (30)
We consider the numerical approximation of second-order semi-linear parabolic stochastic partial differential equations interpreted in the mild sense which we solve on general two-dimensional domains with a C² boundary with homogeneous Dirichlet boundary conditions. The equations are driven by Gaussian additive noise, and several Lipschitz-like conditions are imposed on the nonlinear function. We discretize in space with a spectral Galerkin method and in time using an explicit Euler-like scheme. For irregular shapes, the necessary Dirichlet eigenvalues and eigenfunctions are obtained from a boundary integral equation method. This yields a nonlinear eigenvalue problem, which is discretized using a boundary element collocation method and is solved with the Beyn contour integral algorithm. We present an error analysis as well as numerical results on an exemplary asymmetric shape, and point out limitations of the approach.
Helle Fensterprofilmaterialien : Alterungsverhalten auf Basis von peroxidisch vernetztem EPDM
(2010)
Purpose
In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model.
Material and Methods
Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio).
Results
In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF.
Conclusion
The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.
Die Fallstudie FAYMONVILLE beschäftigt sich damit, wie es dem Familienunternehmen Faymonville aus Ostbelgien gelungen ist, sich zu einem der führenden Hersteller in seiner Branche zu entwickeln. Die gezielte Identifizierung neuer Märkte, die Fokussierung auf die relevanten Kundenbedürfnisse und eine konsistente Produktpolitik mit einem abgestimmten Fertigungskonzept legen die Grundsteine für den Erfolg. Das vorliegende Fallbeispiel zeigt anschaulich, wie es gelingen kann, den prinzipiellen Widerspruch zwischen wirtschaftlicher und kundenindividueller Fertigung erfolgreich aufzulösen.