Refine
Year of publication
- 2024 (59)
- 2023 (237)
- 2022 (286)
- 2021 (282)
- 2020 (227)
- 2019 (377)
- 2018 (255)
- 2017 (258)
- 2016 (268)
- 2015 (301)
- 2014 (286)
- 2013 (299)
- 2012 (310)
- 2011 (323)
- 2010 (328)
- 2009 (360)
- 2008 (310)
- 2007 (312)
- 2006 (330)
- 2005 (303)
- 2004 (323)
- 2003 (254)
- 2002 (250)
- 2001 (221)
- 2000 (245)
- 1999 (236)
- 1998 (242)
- 1997 (220)
- 1996 (202)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (111)
- 1988 (104)
- 1987 (105)
- 1986 (81)
- 1985 (84)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
- 1925 (1)
Document Type
- Article (5586)
- Conference Proceeding (1620)
- Book (1078)
- Part of a Book (548)
- Bachelor Thesis (297)
- Patent (172)
- Report (100)
- Doctoral Thesis (78)
- Other (77)
- Administrative publication (76)
- Part of Periodical (63)
- Lecture (30)
- Master's Thesis (20)
- Contribution to a Periodical (19)
- Review (17)
- Diploma Thesis (15)
- Working Paper (13)
- Course Material (9)
- Talk (7)
- Study Thesis (5)
Language
- German (5012)
- English (4801)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- nld (2)
- Italien (1)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (21)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Corporate Design (17)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- Fotografie (16)
- civil engineering (14)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1138)
- Fachbereich Energietechnik (1104)
- Fachbereich Maschinenbau und Mechatronik (866)
- Fachbereich Chemie und Biotechnologie (847)
- Fachbereich Luft- und Raumfahrttechnik (776)
- Fachbereich Bauingenieurwesen (705)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (613)
- Fachbereich Gestaltung (484)
- Solar-Institut Jülich (339)
- Fachbereich Architektur (174)
- FH Aachen (153)
- ECSM European Center for Sustainable Mobility (112)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (74)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (71)
- Nowum-Energy (70)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.
For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated.
The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements.