Article
Refine
Year of publication
- 2024 (3)
- 2023 (3)
- 2022 (5)
- 2021 (6)
- 2020 (10)
- 2019 (9)
- 2018 (13)
- 2017 (8)
- 2016 (14)
- 2015 (8)
- 2014 (13)
- 2013 (13)
- 2012 (16)
- 2011 (25)
- 2010 (21)
- 2009 (23)
- 2008 (29)
- 2007 (22)
- 2006 (23)
- 2005 (20)
- 2004 (27)
- 2003 (14)
- 2002 (16)
- 2001 (13)
- 2000 (25)
- 1999 (20)
- 1998 (18)
- 1997 (29)
- 1996 (16)
- 1995 (19)
- 1994 (19)
- 1993 (16)
- 1992 (12)
- 1991 (11)
- 1990 (8)
- 1989 (13)
- 1988 (10)
- 1987 (5)
- 1986 (6)
- 1985 (9)
- 1984 (2)
- 1983 (3)
- 1982 (2)
- 1981 (3)
- 1980 (8)
- 1979 (4)
- 1978 (7)
- 1977 (1)
- 1976 (6)
- 1975 (2)
- 1974 (4)
- 1973 (1)
- 1972 (3)
- 1970 (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (637) (remove)
Document Type
- Article (637) (remove)
Keywords
- Multimediamarkt (6)
- Hot S-parameter (2)
- Literaturanalyse (2)
- MINLP (2)
- Referenzmodellierung (2)
- 197m/gHg (1)
- 3-D printing (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Automated driving (1)
Das Ich ist eine Illusion
(1990)
In this paper we present an extension of the action language Golog that allows for using fuzzy notions in non-deterministic argument choices and the reward function in decision-theoretic planning. Often, in decision-theoretic planning, it is cumbersome to specify the set of values to pick from in the non-deterministic-choice-of-argument statement. Also, even for domain experts, it is not always easy to specify a reward function. Instead of providing a finite domain for values in the non-deterministic-choice-of-argument statement in Golog, we now allow for stating the argument domain by simply providing a formula over linguistic terms and fuzzy uents. In Golog’s forward-search DT planning algorithm, these formulas are evaluated in order to find the agent’s optimal policy. We illustrate this in the Diner Domain where the agent needs to calculate the optimal serving order.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.