Refine
Year of publication
- 2024 (6)
- 2023 (17)
- 2022 (20)
- 2021 (12)
- 2020 (13)
- 2019 (16)
- 2018 (22)
- 2017 (12)
- 2016 (44)
- 2015 (30)
- 2014 (46)
- 2013 (29)
- 2012 (40)
- 2011 (28)
- 2010 (34)
- 2009 (30)
- 2008 (16)
- 2007 (20)
- 2006 (17)
- 2005 (20)
- 2004 (15)
- 2003 (14)
- 2002 (19)
- 2001 (18)
- 2000 (12)
- 1999 (16)
- 1998 (31)
- 1997 (25)
- 1996 (19)
- 1995 (36)
- 1994 (29)
- 1993 (21)
- 1992 (27)
- 1991 (15)
- 1990 (20)
- 1989 (20)
- 1988 (19)
- 1987 (16)
- 1986 (11)
- 1985 (7)
- 1984 (10)
- 1983 (10)
- 1982 (3)
- 1981 (3)
- 1980 (3)
- 1979 (8)
- 1978 (2)
- 1976 (2)
- 1975 (3)
- 1973 (2)
- 1972 (2)
- 1971 (2)
Institute
- Fachbereich Chemie und Biotechnologie (912) (remove)
Language
- English (551)
- German (358)
- Multiple languages (2)
- Spanish (1)
Document Type
- Article (602)
- Patent (117)
- Book (65)
- Conference: Meeting Abstract (55)
- Conference Proceeding (35)
- Part of a Book (21)
- Report (6)
- Bachelor Thesis (3)
- Doctoral Thesis (3)
- Conference Poster (1)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biorefinery (2)
- Biotechnological application (2)
- Butanol (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
We present the production of 58mCo on a small, 13 MeV medical cyclotron utilizing a siphon style liquid target system. Different concentrated iron(III)-nitrate solutions of natural isotopic distribution were irradiated at varying initial pressures and subsequently separated by solid phase extraction chromatography. The radio cobalt (58m/gCo and 56Co) was successfully produced with saturation activities of (0.35 ± 0.03) MBq μA−1 for 58mCo with a separation recovery of (75 ± 2) % of cobalt after one separation step utilizing LN-resin.
Production of Y-86 and other radiometals for research purposes using a solution target system
(2015)
In der Biotechnologie stellt Einzelstrang-DNA (ssDNA) eine Schlüsselrolle dar und fungiert z. B. als Baustein für die nanoskalige Feinmechanik oder als Affinitätsligand, ein sog. Aptamer. Hinsichtlich der industriellen Verwendung bieten Aptamere im Vergleich zu Antikörpern viele Vorteile, wie z. B. eine gute Renaturierung bzw. die Selektion für cytotoxische Moleküle. Aktuell wächst die Nachfrage für chimäre Aptamere von bis zu 200 n, um die simultane Bindung bzw. die Modifikation mehrerer Moleküle zu realisieren. Bis heute wird ssDNA mittels einer sequentiellen Synthese hergestellt, die eine Effizienz von ca. 99,5 % je Zyklus und bereits bei einer Produktlänge von 100 n nur noc hAusbeuten von max. 60 % zeigt. Um dem Bedarf an ssDNA im Bereich > 100 n zu entsprechen, wurden zwei enzymatische Verfahren zur Produktion dieser Makronukleotide entworfen. Die erste Technik basiert auf einerFestphasen-PCR und ermöglicht sowohlein Primer- als auch ein Templatrecycling. Das zweite Verfahren beruht auf einer Plasmidbasierten In-vivo-Amplifikation, der sog. AptaGENE®-Technologie. In einer einzigen Klonierung werden bis zu 100 Kopien des Monomers in einen Vektor kloniert. Nach einer Transformation folgt der reguläre Produktionsprozess in Form einer Kultivierung, Plasmidpräparation und sequenziellen Aufarbeitung von bis zu 6 · 10¹⁵ Makronukleotiden pro Milliliter Fermentationsvolumen.
Experimental determination of the cross sections of proton capture on radioactive nuclei is extremely difficult. Therefore, it is of substantial interest for the understanding of the production of the p-nuclei. For the first time, a direct measurement of proton-capture cross sections on stored, radioactive ions became possible in an energy range of interest for nuclear astrophysics. The experiment was performed at the Experimental Storage Ring (ESR) at GSI by making use of a sensitive method to measure (p,γ) and (p,n) reactions in inverse kinematics. These reaction channels are of high relevance for the nucleosyn-thesis processes in supernovae, which are among the most violent explosions in the universe and are not yet well understood. The cross section of the ¹¹⁸Te(p,γ) reaction has been measured at energies of 6 MeV/u and 7 MeV/u. The heavy ions interacted with a hydrogen gas jet target. The radiative recombination process of the fully stripped ¹¹⁸Te ions and electrons from the hydrogen target was used as a luminosity monitor. An overview of the experimental method and preliminary results from the ongoing analysis will be presented.
Ein viel versprechender erneuerbarer Rohstoff für die Produktion von Chemikalien und Treibstoffen ist Lignocellulose aus pflanzlicher Biomasse. Die darin enthaltenen Zucker können mittels enzymatischer Hydrolyse freigesetzt und fermentativ zu Ethanol umgesetzt werden. Ein interessanter Ansatz ist dabei die simultane Verzuckerung und Fermentation. Hefen und Enzyme haben mit 30 °C bzw. 50 °C zwar unterschiedliche Temperaturoptima, es konnte aber gezeigt werden, dass auch bei den niedrigeren Temperaturen eine Umsetzung der Cellulose zu Glucose erfolgt, wenn auch langsamer als bei optimalen Bedingungen. Außerdem konnte in Vorversuchen gezeigt werden, dass Ethanol in den zu erwartenden Konzentrationen keinen Einfluss auf die enzymatische Umsetzung hat.
Prozessintegrierte Magnetseparation im Labormaßstab mittels High-Gradient Magnetic Separator (HGMS)
(2014)
Die Hochgradient-Magnetseparation (HGMS) stellt eine Alternative zu konventionellen Methoden der Proteinaufarbeitung wie Filtration und Chromatographie dar und dient zudem als Prozessintensivierung. Bisherige Separatoren sind für Anwendungen von mehreren Litern Prozessvolumina Fermentationsmedium und Gramm Magnetpartikel ausgelegt. Bei der Entwicklung und Anwendung neuartiger Magnetpartikeloberflächen ist die Verfügbarkeit großer Mengen nicht gegeben. Bisherige Filterkammern erhöhen zudem den Arbeitsaufwand und verursachen größere Partikelverluste bei Spülvorgängen oder der Reinigung aufgrund der Partikeladsorption. Für Anwendungen im Maßstab < 500 mL wird deshalb ein Miniatur-Hochgradientfilter (miniHGF) entwickelt. Das Modell wird im 3D-Drucker Makerbot Replicator 2 gefertigt und magne-isierbare Drähte zur Partikelabscheidung eingesetzt. Die Vergleichbarkeit mit einem etablierten Magnetseparator wird anhand der Aufnahme von Durchbruchskurven und Bestimmung der Filtereffizienz untersucht. Die Praxistauglichkeit mit kleinen Volumina wird in wiederholten Batch-Versuchen mit auf Magnetpartikeln immobilisiertem Enzym und einem kolorimetrischen Assay geprüft.