Article
Refine
Year of publication
- 2023 (22) (remove)
Document Type
- Article (22) (remove)
Language
- English (22) (remove)
Keywords
- ultrasound (2)
- Architectural design (1)
- Bacillus atrophaeus spores (1)
- Bacterial cellulose (1)
- Bioabsorbable (1)
- Capacitive field-effect sensor (1)
- Carbon sources (1)
- Cellulose nanostructure (1)
- Competitiveness (1)
- Conductive Boundary Condition (1)
- Cost-effectiveness (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Culture media (1)
- DPA (dipicolinic acid) (1)
- E-Mobility (1)
- Endothelial dysfunction (1)
- Energy-intensive industry (1)
- Enterprise information systems (1)
- Fault approximation (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (22) (remove)
In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin-film magnesium-based meander-like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium-based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue-like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium-based layers. The 3-layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C.
In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive–voltage (C–V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles.