Refine
Year of publication
- 2015 (284) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (38)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (31)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Elektrotechnik und Informationstechnik (30)
- Fachbereich Bauingenieurwesen (26)
- Fachbereich Energietechnik (23)
- Fachbereich Maschinenbau und Mechatronik (22)
Has Fulltext
- no (284) (remove)
Document Type
- Article (125)
- Conference Proceeding (78)
- Part of a Book (39)
- Book (21)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
Rugged terrain robot designs are important for field robotics missions. A number of commercial platforms are available, however, at an impressive price. In this paper, we describe the hardware and software component of a low-cost wheeled rugged-terrain robot. The robot is based on an electric children quad bike and is modified to be driven by wire. In terms of climbing properties, operation time and payload it can compete with some of the commercially available platforms, but at a far lower price.
Simultane Atline-Quantifizierung von Magnetpartikeln und Mikroorganismen bei einer HGMS-Filtration
(2015)
Es wird eine neue Atline-Messmethode vorgestellt, mit der während einer Hochgradienten-Magnetseparation (HGMS)-Filtration eine simultane Quantifizierung von Magnetpartikeln und Mikroorganismen im Filtrat vorgenommen werden kann. Dabei gelingt die Quantifizierung signifikant besser als mit bisher verwendeten Messmethoden. Mit dieser Methode ist es möglich, die Trennleistung einer HGMS-Filtration zu bestimmen und einen Filterdurchbruch durch Konzentrationsanstiege im Bereich einiger µg L−1 von Magnetpartikeln im Filtrat frühzeitig zu detektieren, ohne dass nennenswerte Partikelmengen verloren gehen.
We present an electromechanically coupled Finite Element model for cardiac tissue. It bases on the mechanical model for cardiac tissue of Hunter et al. that we couple to the McAllister-Noble-Tsien electrophysiological model of purkinje fibre cells. The corresponding system of ordinary differential equations is implemented on the level of the constitutive equations in a geometrically and physically nonlinear version of the so-called edge-based smoothed FEM for plates. Mechanical material parameters are determined from our own pressure-deflection experimental setup. The main purpose of the model is to further examine the experimental results not only on mechanical but also on electrophysiological level down to ion channel gates. Moreover, we present first drug treatment simulations and validate the model with respect to the experiments.
Capacitive field-effect electrolyte-insulator-semiconductor sensors consisting of an Al-p-Si-SiO2 structure have been used for the electrical detection of unlabelled single- and double-stranded DNA (dsDNA) molecules by their intrinsic charge. A simple functionalization protocol based on the layer-by-layer (LbL) technique was used to prepare a weak polyelectrolyte/probe-DNA bilayer, followed by the hybridization with complementary target DNA molecules. Due to the flat orientation of the LbL-adsorbed DNA molecules, a high sensor signal has been achieved. In addition, direct label-free detection of in-solution hybridized dsDNA molecules has been studied.
Capacitive field-effect sensors modified with a multi-enzyme membrane have been applied for an electronic transduction of biochemical signals processed by enzyme-based AND-Reset and OR-Reset logic gates. The local pH change at the sensor surface induced by the enzymatic reaction was used for the activation of the Reset function for the first time.
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.