Refine
Year of publication
- 2015 (284) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (38)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (31)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Elektrotechnik und Informationstechnik (30)
- Fachbereich Bauingenieurwesen (26)
- Fachbereich Energietechnik (23)
- Fachbereich Maschinenbau und Mechatronik (22)
Has Fulltext
- no (284) (remove)
Document Type
- Article (125)
- Conference Proceeding (78)
- Part of a Book (39)
- Book (21)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
"Holzbau kompakt" wurde sowohl für Studierende als auch Praktiker konzipiert und beschränkt sich nicht auf reine Holzbauaufgaben, sondern setzt sich ggf. auch mit der Tragwerkslehre auseinander. Die Neuauflage basiert auf dem Eurocode 5 und berücksichtigt zahlreiche neue Erkenntnisse aus Forschung und praxisnaher Entwicklung. Neben den Grundlagen der Bemessung, der Baustoffe, der Dauerhaftigkeit und des Brandschutzes konzentriert sich das Grundlagenwerk besonders auf das Konstruieren mit Holz und Holzwerkstoffen, anschaulich dargestellt an sehr ausführlichen Beispielen für Wohnhaus und Hallentragwerk.
In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor.
An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.