Refine
Year of publication
- 2021 (229) (remove)
Institute
- Fachbereich Gestaltung (55)
- Fachbereich Medizintechnik und Technomathematik (46)
- IfB - Institut für Bioengineering (32)
- Fachbereich Elektrotechnik und Informationstechnik (26)
- Fachbereich Luft- und Raumfahrttechnik (23)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Energietechnik (19)
- Fachbereich Bauingenieurwesen (13)
- ECSM European Center for Sustainable Mobility (10)
- Fachbereich Maschinenbau und Mechatronik (10)
Has Fulltext
- no (229) (remove)
Document Type
- Article (90)
- Conference Proceeding (52)
- Bachelor Thesis (49)
- Part of a Book (17)
- Book (6)
- Master's Thesis (4)
- Report (4)
- Doctoral Thesis (2)
- Review (2)
- Conference: Meeting Abstract (1)
Keywords
- Animation (3)
- Holz (3)
- Mode (3)
- Nachhaltigkeit (3)
- Redesign (3)
- UX Design (3)
- App (2)
- Bookazine (2)
- Corporate Design (2)
- Corporate Identity (2)
The aim of the current study was to investigate the performance of integrated RF
transmit arrays with high channel count consisting of meander microstrip antennas
for body imaging at 7 T and to optimize the position and number of transmit ele-
ments. RF simulations using multiring antenna arrays placed behind the bore liner
were performed for realistic exposure conditions for body imaging. Simulations were
performed for arrays with as few as eight elements and for arrays with high channel
counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of
freedom for RF shimming in the abdomen. Worst-case specific absorption rate
(SARwc ), SAR overestimation in the matrix compression, the number of virtual obser-
vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming
was performed in differently oriented regions of interest in the body, and the devia-
tion from a target B1+ field was evaluated. Results show that integrated multiring
arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe-
cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical
workflow; however, a low duty cycle or a high SAR is required to achieve homoge-
neous B1+ distributions and to exploit the full potential. In conclusion, integrated
arrays allow for high element counts that have high degrees of freedom for the pulse
optimization but also produce high SARwc , which reduces the SAR accuracy in the
VOP compression for low-SAR protocols, leading to a potential reduction in array
performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a
high number of VOPs, which increases the computational cost for VOP evaluation
and makes online SAR monitoring or pulse optimization challenging. Arrays with
interleaved rings showed the best results in the study.
Wir stellen hier exemplarisch STACK Aufgaben vor, die frei von der Problematik sind, welche sich durch diverse Kommunikationswege und (webbasierte) Computer Algebra Systeme (CAS) ergibt. Daher sind sie insbesondere für eine Open-Book Online Prüfung geeignet, da eine faire Prüfungssituation gewährleistet werden kann.
Dieses Lehrbuch vermittelt die Grundlagen der Wärmeübertragung sowie den Umgang mit EXCEL-VBA von der Erstellung von Makros bis zu benutzerdefinierten Funktionen. Es legt damit eine Basis für die schnelle und professionelle Durchführung von Berechnungen und Simulationen. Die angeleitete Erstellung von Berechnungsmodulen mit EXCEL und VBA aus allen wichtigen Bereichen der Wärmeübertragung bildet den inhaltlichen Schwerpunkt. Dazu zählen die stationäre Wärmeleitung und der stationäre Wärmedurchgang, die instationäre Wärmeleitung, der Wärmeübergang bei freier und erzwungener Konvektion sowie die Wärmestrahlung und der Wärmeübergang beim Kondensieren und Sieden. Soweit sinnvoll und möglich werden die Stoffwertekorrelationen und die Berechnungsvorschriften aus dem VDI-Wärmeatlas verwendet. Für ausgewählte Anwendungen werden zudem komplexere Auslegungen und Simulationen von Prozessen der Wärmeübertragung sowie von Wärmeübertragern erstellt. Die Zielgruppen: Studierende in Bachelor- und Masterstudiengängen, Praktiker im Engineering
The Robot Operating System (ROS) is the current de-facto standard in robot middlewares. The steadily increasing size of the user base results in a greater demand for training as well. User groups range from students in academia to industry professionals with a broad spectrum of developers in between. To deliver high quality training and education to any of these audiences, educators need to tailor individual curricula for any such training. In this paper, we present an approach to ease compiling curricula for ROS trainings based on a taxonomy of the teaching contents. The instructor can select a set of dedicated learning units and the system will automatically compile the teaching material based on the dependencies of the units selected and a set of parameters for a particular training. We walk through an example training to illustrate our work.
7T MR Safety
(2021)
Let´s change fashion!: Eine Image-Kampagne der Fair Wear Foundation
für faire und nachhaltige Mode.
(2021)
Fast Fashion-Ketten beherrschen die Modewelt. Doch einige Unternehmen, Siegel und Stiftungen versuchen die Textilindustrie neu umzugestalten. Um die Modeindustrie nachhaltig zu verändern, müssen allerdings auch den Kunden die schlechten Arbeitsbedingungen und die negativen Einflüsse der Textilbranche auf die Umwelt bewusst werden.
Das konkrete Ziel der erstellten Kampagne ist es, modebewusste Menschen davon zu überzeugen Fast Fashion hinter sich zu lassen. Es soll also ein Umdenken bei den Konsumenten stattfinden. Die Fair Wear Foundation und ihre Mitglieder vertreten die Vision, dass Mode auch fair und nachhaltig sein kann. Genau diese Vision soll mit der Kampagne vermittelt und an die Konsumenten weitergetragen werden.
A new method for improved autoclave loading within the restrictive framework of helicopter manufacturing is proposed. It is derived from experimental and numerical studies of the curing process and aims at optimizing tooling positions in the autoclave for fast and homogeneous heat-up. The mold positioning is based on two sets of information. The thermal properties of the molds, which can be determined via semi-empirical thermal simulation. The second information is a previously determined distribution of heat transfer coefficients inside the autoclave. Finally, an experimental proof of concept is performed to show a cycle time reduction of up to 31% using the proposed methodology.
Magnetic nanoparticle relaxation in biomedical application: focus on simulating nanoparticle heating
(2021)
Dual frequency magnetic excitation of magnetic nanoparticles (MNP) enables enhanced biosensing applications. This was studied from an experimental and theoretical perspective: nonlinear sum-frequency components of MNP exposed to dual-frequency magnetic excitation were measured as a function of static magnetic offset field. The Langevin model in thermodynamic equilibrium was fitted to the experimental data to derive parameters of the lognormal core size distribution. These parameters were subsequently used as inputs for micromagnetic Monte-Carlo (MC)-simulations. From the hysteresis loops obtained from MC-simulations, sum-frequency components were numerically demodulated and compared with both experiment and Langevin model predictions. From the latter, we derived that approximately 90% of the frequency mixing magnetic response signal is generated by the largest 10% of MNP. We therefore suggest that small particles do not contribute to the frequency mixing signal, which is supported by MC-simulation results. Both theoretical approaches describe the experimental signal shapes well, but with notable differences between experiment and micromagnetic simulations. These deviations could result from Brownian relaxations which are, albeit experimentally inhibited, included in MC-simulation, or (yet unconsidered) cluster-effects of MNP, or inaccurately derived input for MC-simulations, because the largest particles dominate the experimental signal but concurrently do not fulfill the precondition of thermodynamic equilibrium required by Langevin theory.