Article
Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (623) (remove)
Has Fulltext
- no (623) (remove)
Document Type
- Article (623) (remove)
Keywords
- Hot S-parameter (2)
- Literaturanalyse (2)
- MINLP (2)
- Referenzmodellierung (2)
- 197m/gHg (1)
- 3-D printing (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Automated driving (1)
- Automotive application (1)
- Benchmark (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CAV (1)
- CO2 (1)
- Cardiovascular Magnetic Resonance (1)
- Chance Constraint (1)
- Chatbots (1)
- Circuit simulation (1)
- Competence Developing Games (1)
- Design Science Research (1)
- Digitalisierung (1)
- E-Learning (1)
- EBSCO Discovery Service (1)
- EGG (1)
- Energy-efficient ventilation (1)
- Engineering Application (1)
- Enhanced Telecom Operations Map (1)
- Experimental validation (1)
- Forschungsprozess (1)
- Furnace (1)
- Fusion (1)
- Game-based learning (1)
- Gold nanoparticle (AuNP) (1)
- High field MRI (1)
- IBM Watson Explorer (1)
- IP-based networks (1)
- IT security education (1)
- Image Quality Assessment (1)
- Image Quality Score (1)
- Indoor air quality (1)
- Indoor environmental quality (1)
- Interval Time Series (1)
- Keyword analysis (1)
- Larynx position (1)
- Li7La3Zr2O12 (1)
- LiDAR (1)
- LiGaO2 (1)
- Lidar (1)
- Literaturrecherche (1)
- MILP (1)
- MR safety (1)
- MRI (1)
- Magneto alert sensor (1)
- Meitner-Auger-electron (MAE) (1)
- Mode converter (1)
- Modeling (1)
- NGN (1)
- PM2.5 (1)
- Plasma (1)
- Plasma diagnostics (1)
- Powertrain (1)
- Praxisprojekte (1)
- Process virtualization (1)
- Product bundling (1)
- Prozessabläufe (1)
- Prozessautomatisierung (1)
- Prozessmodellierung (1)
- Prozessstandardisierung (1)
- Pump System (1)
- Pumping systems (1)
- RANSAC (1)
- Radar (1)
- Robotic Process Automation (1)
- Rotary encoder (1)
- Self-driving (1)
- Services (1)
- Sound Pressure Level (1)
- Stochastic Programming (1)
- Targeted radionuclide therapy (TRT) (1)
- Technical Operations Research (1)
- Telecommunication (1)
- Text Analytics (1)
- Text Analytics (1)
- Text Mining (1)
- Tomography (1)
- Transfer impedance (1)
- Transformation (1)
- Uktrahigh field MRI (1)
- Uncertainty (1)
- VOP compression (1)
- Voice assessment (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Wiegand sensor (1)
- automated parking (1)
- automated vehicles (1)
- availability (1)
- batteries and fuel cells (1)
- body imaging at 7 T MRI (1)
- body imaging at UHF MRI (1)
- connected automated vehicles (1)
- design of technical systems (1)
- eTOM (1)
- electrospinning (1)
- energy efficiency (1)
- energy transfer (1)
- experimental evaluation (1)
- fibers (1)
- ga-doping (1)
- garnet solid electrolyte (1)
- genetic algorithm (1)
- global optimization (1)
- harmonic radar (1)
- harmonic radar tags (1)
- heating system (1)
- ignition (1)
- integrated transmit coil arrays (1)
- irradiation (1)
- legal obligations (1)
- line detection (1)
- mathematical optimization (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mixed-integer linear programming (1)
- next generation network (1)
- nonlinear VNA measurements (1)
- optimization (1)
- parking slot detection (1)
- plasma jet (1)
- point cloud processing (1)
- porous materials (1)
- product bundling (1)
- product liability (1)
- programming (1)
- remote sensing (1)
- resilience (1)
- slum classification (1)
- solid-state battery (1)
- stochastic optimization (1)
- sustainability (1)
- system optimization (1)
- system synthesis (1)
- technical operations research (1)
- telecommunication (1)
- thermal dose (1)
- tissue temperature (1)
- transmit antenna arrays (1)
- water supply design (1)
Given industrial applications, the costs for the operation and maintenance of a pump system typically far exceed its purchase price. For finding an optimal pump configuration which minimizes not only investment, but life-cycle costs, methods like Technical Operations Research which is based on Mixed-Integer Programming can be applied. However, during the planning phase, the designer is often faced with uncertain input data, e.g. future load demands can only be estimated. In this work, we deal with this uncertainty by developing a chance-constrained two-stage (CCTS) stochastic program. The design and operation of a booster station working under uncertain load demand are optimized to minimize total cost including purchase price, operation cost incurred by energy consumption and penalty cost resulting from water shortage. We find optimized system layouts using a sample average approximation (SAA) algorithm, and analyze the results for different risk levels of water shortage. By adjusting the risk level, the costs and performance range of the system can be balanced, and thus the
system’s resilience can be engineered
Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers
(2014)
Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.
This article addresses the need for an innovative technique in plasma shaping, utilizing antenna structures, Maxwell’s laws, and boundary conditions within a shielded environment. The motivation lies in exploring a novel approach to efficiently generate high-energy density plasma with potential applications across various fields. Implemented in an E01 circular cavity resonator, the proposed method involves the use of an impedance and field matching device with a coaxial connector and a specially optimized monopole antenna. This setup feeds a low-loss cavity resonator, resulting in a high-energy density air plasma with a surface temperature exceeding 3500 o C, achieved with a minimal power input of 80 W. The argon plasma, resembling the shape of a simple monopole antenna with modeled complex dielectric values, offers a more energy-efficient alternative compared to traditional, power-intensive plasma shaping methods. Simulations using a commercial electromagnetic (EM) solver validate the design’s effectiveness, while experimental validation underscores the method’s feasibility and practical implementation. Analyzing various parameters in an argon atmosphere, including hot S -parameters and plasma beam images, the results demonstrate the successful application of this technique, suggesting its potential in coating, furnace technology, fusion, and spectroscopy applications.
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Verfügbarkeit und Nachhaltigkeit sind wichtige Anforderungen bei der Planung langlebiger technischer Systeme. Meist werden bei Lebensdaueroptimierungen lediglich einzelne Komponenten vordefinierter Systeme untersucht. Ob eine optimale Lebensdauer eine gänzlich andere Systemvariante bedingt, wird nur selten hinterfragt. Technical Operations Research (TOR) erlaubt es, aus Obermengen technischer Systeme automatisiert die lebensdaueroptimale Systemstruktur auszuwählen. Der Artikel zeigt dies am Beispiel eines hydrostatischen Getriebes.
Objectives
Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T.
Methods
A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated.
Results
All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm.
Conclusions
This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.