Refine
Year of publication
- 2012 (313) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Chemie und Biotechnologie (39)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- Fachbereich Bauingenieurwesen (30)
- INB - Institut für Nano- und Biotechnologien (30)
- IfB - Institut für Bioengineering (29)
- Fachbereich Maschinenbau und Mechatronik (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Has Fulltext
- no (313) (remove)
Document Type
- Article (129)
- Conference Proceeding (81)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Doctoral Thesis (6)
- Report (3)
- Habilitation (1)
- Other (1)
Keywords
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Avalanche (1)
Determination of the frictional coefficient of the implant-antler interface : experimental approach
(2012)
The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface.
In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed.
Die Aufrechnung des Insolvenzverwalters gegen eine Insolvenzforderung nach ihrer Feststellung
(2012)
Mit einer aktuellen Entscheidung hat der BGH, Urt. v. 11.5.2012 - V ZR 196/11, MDR 2012, 958 seine Rechtsprechung v. 5.6.2008 - V ZB 85/07 zur Entstehungsphase einer Wohnungseigentümergemeinschaft fortgeführt. In dieser Entscheidung sieht der BGH die Erwerber von Wohnungseigentum als Kostenschuldner gem. § 16 Abs. 2 WEG an, obwohl diese noch nicht im Grundbuch eingetragen sind. Eine andere Rechtslage besteht beim sog. Zweiterwerb. Die Abgrenzung von Erstund Zweierwerb ist aufgrund der völlig unterschiedlichen Rechtsfolgen für die Praxis von großer Bedeutung.