Refine
Year of publication
Document Type
- Article (5464)
- Conference Proceeding (1393)
- Book (1056)
- Part of a Book (544)
- Patent (172)
- Bachelor Thesis (156)
- Report (81)
- Doctoral Thesis (78)
- Other (68)
- Contribution to a Periodical (19)
- Master's Thesis (17)
- Review (17)
- Working Paper (8)
- Talk (5)
- Habilitation (4)
- Preprint (4)
- Diploma Thesis (3)
- Poster (3)
- Part of Periodical (2)
- Examination Thesis (1)
Language
Has Fulltext
- no (9096) (remove)
Keywords
- Corporate Design (9)
- Illustration (9)
- Erscheinungsbild (8)
- Gamification (8)
- Nachhaltigkeit (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Digitalisierung (6)
- avalanche (6)
- App (5)
- Earthquake (5)
- Editorial (5)
- Enterprise Architecture (5)
- Fotografie (5)
- Geschichte (5)
- MINLP (5)
- solar sail (5)
- Aktionskunst (4)
- Design (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (1907)
- Fachbereich Elektrotechnik und Informationstechnik (1116)
- Fachbereich Wirtschaftswissenschaften (1100)
- Fachbereich Energietechnik (1056)
- Fachbereich Chemie und Biotechnologie (829)
- Fachbereich Maschinenbau und Mechatronik (799)
- Fachbereich Luft- und Raumfahrttechnik (749)
- Fachbereich Bauingenieurwesen (658)
- IfB - Institut für Bioengineering (623)
- INB - Institut für Nano- und Biotechnologien (584)
- Solar-Institut Jülich (334)
- Fachbereich Gestaltung (333)
- Fachbereich Architektur (161)
- ECSM European Center for Sustainable Mobility (106)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (66)
- Nowum-Energy (64)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (62)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (21)
- Freshman Institute (19)
- Kommission für Forschung und Entwicklung (18)
- Verwaltung (11)
- IaAM - Institut für angewandte Automation und Mechatronik (4)
- FH Aachen (3)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (2)
- Datenverarbeitungszentrale (1)
- Digitalisierung in Studium & Lehre (1)
Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element.
Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis.
„Work Habitat“ ist eine markenorientierte Officelösung, die auf skalierbare Weise mit einem Start-up mitwächst und in Kooperation mit dem Unternehmen academa GmbH entstanden ist. Diese Brand Experience fördert Teambuilding und Identifikation mit dem Unternehmen. Sie passt sich an die Teammitglieder an, indem sie einen ganzheitlichen Blick auf das Office-System bewahrt. Ferner stellt sie eine nahtlose Verbindung digitaler und analoger Arbeitswelten dar und bietet eine einladende Umgebung verschiedener Arten zu Arbeiten an: von Deep-Focus bis zur kooperativen Zusammenarbeit und der Anregung zwangloser Begegnungen. Die modularen Komponenten können trotz Veränderungen, Umzügen oder unerwartet rasanten Entwicklungen nachhaltig und flexibel eingesetzt werden. Eine schnelllebige Welt erfordert eine angebrachte, sich ihr anpassende New-Work-Umgebung.
Kindertagesstätten bieten Kleinkindern den Zugang zu unbeschwertem und spielerischem Lernen. Was also, wenn schon der Eingangsbereich die Reizüberflutung bereit hält, der Stauraum der Entfaltung der Kinder nicht gerecht wird und ihre Eigenständigkeit ungefördert bleibt? Es kommt zu unzufriedenen Kindern und Frustration aller Beteilligten. "KIWA" ist das Garderobensystem für Kinder zur Stärkung der heranwachsenden Selbstständigkeit. Mithilfe von persönlichen Wiedererkennungsmerkmalen wird Eigenverantwortung geschult. Leicht und sicher zu erreichender Stauraum sorgt für Ordnung. Spielerisches lernen trotz Ordnung.
Digital twins enable the modeling and simulation of real-world entities
(objects, processes or systems), resulting in improvements in the associated value
chains. The emerging field of quantum computing holds tremendous promise for
evolving this virtualization towards Quantum (Digital) Twins (QDT) and
ultimately Quantum Twins (QT). The quantum (digital) twin concept is not a
contradiction in terms - but instead describes a hybrid approach that can be
implemented using the technologies available today by combining classical
computing and digital twin concepts with quantum processing. This paper
presents the status quo of research and practice on quantum (digital) twins. It also
discuses their potential to create competitive advantage through real-time
simulation of highly complex, interconnected entities that helps companies better
address changes in their environment and differentiate their products and
services.
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.
NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.
Lignin is a promising renewable biopolymer being investigated worldwide as an environmentally benign substitute of fossil-based aromatic compounds, e.g. for the use as an excipient with antioxidant and antimicrobial properties in drug delivery or even as active compound. For its successful implementation into process streams, a quick, easy, and reliable method is needed for its molecular weight determination. Here we present a method using 1H spectra of benchtop as well as conventional NMR systems in combination with multivariate data analysis, to determine lignin’s molecular weight (Mw and Mn) and polydispersity index (PDI). A set of 36 organosolv lignin samples (from Miscanthus x giganteus, Paulownia tomentosa and Silphium perfoliatum) was used for the calibration and cross validation, and 17 samples were used as external validation set. Validation errors between 5.6% and 12.9% were achieved for all parameters on all NMR devices (43, 60, 500 and 600 MHz). Surprisingly, no significant difference in the performance of the benchtop and high-field devices was found. This facilitates the application of this method for determining lignin’s molecular weight in an industrial environment because of the low maintenance expenditure, small footprint, ruggedness, and low cost of permanent magnet benchtop NMR systems.
Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data.