Refine
Year of publication
- 2024 (47) (remove)
Document Type
- Article (14)
- Part of a Book (13)
- Bachelor Thesis (7)
- Conference Proceeding (6)
- Book (5)
- Patent (1)
- Preprint (1)
Has Fulltext
- no (47) (remove)
Keywords
- Dokumentarfilm (2)
- Hot S-parameter (2)
- 1P hub loads (1)
- 3-D printing (1)
- Aeroelasticity (1)
- Ageing (1)
- Anatomy (1)
- Anomalieerkennung (1)
- BIM (1)
- Buchbindekunst (1)
- Capacitive model (1)
- Cardistry (1)
- Circuit simulation (1)
- Complex-valued eigenvalues (1)
- Constitutive model (1)
- Damage mechanics theory (1)
- Deutschland (1)
- DiggiTwin (1)
- Digital Artistry (1)
- Digitalisierung (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (14)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Gestaltung (7)
- IfB - Institut für Bioengineering (7)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- INB - Institut für Nano- und Biotechnologien (4)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Chemie und Biotechnologie (2)
- Fachbereich Luft- und Raumfahrttechnik (2)
- Fachbereich Wirtschaftswissenschaften (2)
- Fachbereich Architektur (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Institut fuer Angewandte Polymerchemie (1)
Schalung und Gerüste
(2024)
Systemschalungen und Systemgerüste haben den Baustellenbetrieb in vielen Bereichen sehr vereinfacht. Dennoch sind Kenntnisse in diesen Feldern für eine erfolgreiche und effektive Bauleitung unverzichtbar. In diesem Kapitel werden Hinweise und Empfehlungen für die Bemessung und Einsatz von Schalungen, Trag- und Arbeitsgerüsten für den Baustellenbetrieb gegeben.
Kein Bauvorhaben sollte realisiert werden, ohne dass es auf einer vertraglichen Grundlage zwischen Auftraggeber und Auftragnehmer fußt. Diese vertragliche Grundlage zu kennen ist essenziell, um dementsprechend handeln zu können. Denn nur wer seine eigenen Rechte und auch Pflichten kennt, kann sich auf diese berufen.
Analyzing electroencephalographic (EEG) time series can be challenging, especially with deep neural networks, due to the large variability among human subjects and often small datasets. To address these challenges, various strategies, such as self-supervised learning, have been suggested, but they typically rely on extensive empirical datasets. Inspired by recent advances in computer vision, we propose a pretraining task termed "frequency pretraining" to pretrain a neural network for sleep staging by predicting the frequency content of randomly generated synthetic time series. Our experiments demonstrate that our method surpasses fully supervised learning in scenarios with limited data and few subjects, and matches its performance in regimes with many subjects. Furthermore, our results underline the relevance of frequency information for sleep stage scoring, while also demonstrating that deep neural networks utilize information beyond frequencies to enhance sleep staging performance, which is consistent with previous research. We anticipate that our approach will be advantageous across a broad spectrum of applications where EEG data is limited or derived from a small number of subjects, including the domain of brain-computer interfaces.
Positionssensorvorrichtung
(2024)
Die Erfindung betrifft eine Positionssensorvorrichtung zur Bestimmung einer Absolutposition eines beweglichen ersten Teils relativ zu einem ortsfesten zweiten Teil mit einem mit dem beweglichen ersten Teil gekoppelter Codekörper, der dazu eingerichtet ist, eine Codespur mit einer Mehrzahl von in Spurrichtung aufeinanderfolgenden Codeelementen zu enthalten zur Bildung eines Codewortes, mit einer magnetischen Detektionseinrichtung zur Detektion der Codespur, wobei die Detektionseinrichtung zum einen an dem Codekörper befestigte und entlang der Spurrichtung in einem solchen Abstand gegenpolig zueinander angeordnete Permanentmagneten aufweist, dass der Abstand mit einer vorgegebenen Länge der jeweiligen Codeelemente übereinstimmt, und zum anderen eine Anzahl von ortsfest und quer zu dem Codekörper versetzt
angeordnete Wiegandsensoren aufweist, wobei der Abstand des Wiegandsensors zu einer Erstreckungsebene der Permanentmagneten derart gewählt ist, dass bei Überdeckung des Wiegandsensors durch den Permanentmagneten ein Wiegandpuls in dem Wiegandsensor induziert wird.
"Out of the Box" ist ein Dokumentarfilm und bietet einen Einblick in die Welt des "Cardistry". Der Schwerpunkt liegt auf dieser Nischenkunst und -kultur der visuell ansprechenden Kartenmanipulation. Der Film beleuchtet den Beginn, die Entwicklung und die lebendige Gemeinschaft hinter dieser einzigartigen Kunstform. Darüber hinaus werden Abgrenzungen, Ursprünge und Ähnlichkeiten zur Kartenmagie erforscht.
This paper investigates the interior transmission problem for homogeneous media via eigenvalue trajectories parameterized by the magnitude of the refractive index. In the case that the scatterer is the unit disk, we prove that there is a one-to-one correspondence between complex-valued interior transmission eigenvalue trajectories and Dirichlet eigenvalues of the Laplacian which turn out to be exactly the trajectorial limit points as the refractive index tends to infinity. For general simply-connected scatterers in two or three dimensions, a corresponding relation is still open, but further theoretical results and numerical studies indicate a similar connection.
Muscle function is compromised by gravitational unloading in space affecting overall musculoskeletal health. Astronauts perform daily exercise programmes to mitigate these effects but knowing which muscles to target would optimise effectiveness. Accurate inflight assessment to inform exercise programmes is critical due to lack of technologies suitable for spaceflight. Changes in mechanical properties indicate muscle health status and can be measured rapidly and non-invasively using novel technology. A hand-held MyotonPRO device enabled monitoring of muscle health for the first time in spaceflight (> 180 days). Greater/maintained stiffness indicated countermeasures were effective. Tissue stiffness was preserved in the majority of muscles (neck, shoulder, back, thigh) but Tibialis Anterior (foot lever muscle) stiffness decreased inflight vs. preflight (p < 0.0001; mean difference 149 N/m) in all 12 crewmembers. The calf muscles showed opposing effects, Gastrocnemius increasing in stiffness Soleus decreasing. Selective stiffness decrements indicate lack of preservation despite daily inflight countermeasures. This calls for more targeted exercises for lower leg muscles with vital roles as ankle joint stabilizers and in gait. Muscle stiffness is a digital biomarker for risk monitoring during future planetary explorations (Moon, Mars), for healthcare management in challenging environments or clinical disorders in people on Earth, to enable effective tailored exercise programmes.
Magnetic nanoparticles (MNP) are investigated with great interest for biomedical applications in diagnostics (e.g. imaging: magnetic particle imaging (MPI)), therapeutics (e.g. hyperthermia: magnetic fluid hyperthermia (MFH)) and multi-purpose biosensing (e.g. magnetic immunoassays (MIA)). What all of these applications have in common is that they are based on the unique magnetic relaxation mechanisms of MNP in an alternating magnetic field (AMF). While MFH and MPI are currently the most prominent examples of biomedical applications, here we present results on the relatively new biosensing application of frequency mixing magnetic detection (FMMD) from a simulation perspective. In general, we ask how the key parameters of MNP (core size and magnetic anisotropy) affect the FMMD signal: by varying the core size, we investigate the effect of the magnetic volume per MNP; and by changing the effective magnetic anisotropy, we study the MNPs’ flexibility to leave its preferred magnetization direction. From this, we predict the most effective combination of MNP core size and magnetic anisotropy for maximum signal generation.
Frequency mixing magnetic detection (FMMD) is a sensitive and selective technique to detect magnetic nanoparticles (MNPs) serving as probes for binding biological targets. Its principle relies on the nonlinear magnetic relaxation dynamics of a particle ensemble interacting with a dual frequency external magnetic field. In order to increase its sensitivity, lower its limit of detection and overall improve its applicability in biosensing, matching combinations of external field parameters and internal particle properties are being sought to advance FMMD. In this study, we systematically probe the aforementioned interaction with coupled Néel–Brownian dynamic relaxation simulations to examine how key MNP properties as well as applied field parameters affect the frequency mixing signal generation. It is found that the core size of MNPs dominates their nonlinear magnetic response, with the strongest contributions from the largest particles. The drive field amplitude dominates the shape of the field-dependent response, whereas effective anisotropy and hydrodynamic size of the particles only weakly influence the signal generation in FMMD. For tailoring the MNP properties and parameters of the setup towards optimal FMMD signal generation, our findings suggest choosing large particles of core sizes dc > 25 nm nm with narrow size distributions (σ < 0.1) to minimize the required drive field amplitude. This allows potential improvements of FMMD as a stand-alone application, as well as advances in magnetic particle imaging, hyperthermia and magnetic immunoassays.