Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1184) (remove)
Language
- English (719)
- German (464)
- Multiple languages (1)
Document Type
- Article (637)
- Conference Proceeding (302)
- Book (114)
- Part of a Book (64)
- Patent (17)
- Report (9)
- Other (8)
- Conference: Meeting Abstract (6)
- Contribution to a Periodical (6)
- Course Material (6)
Keywords
- Multimediamarkt (7)
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Gamification (4)
- Serious Game (4)
- Auslenkung (3)
- Digitale Transformation (3)
- Digitalisierung (3)
- Education (3)
- Javasimulation (3)
- Literaturanalyse (3)
- Optimization (3)
- Powertrain (3)
- Referenzmodellierung (3)
- Robotic Process Automation (3)
- Technical Operations Research (3)
- Telecommunication (3)
- Amplitude (2)
- Autonomous mobile robots (2)
- Competence Developing Games (2)
- Content Management (2)
- Energy efficiency (2)
- Engineering education (2)
- Experimental validation (2)
- Feder (2)
- Forschungsprozess (2)
- Hot S-parameter (2)
- Industry 4.0 (2)
- Machine Learning (2)
- Mathematik (2)
- Multi-robot systems (2)
- Optimal Topology (2)
- Process engineering (2)
- Prozessautomatisierung (2)
- Pump System (2)
- Simulation (2)
- Smart Building (2)
- Smart factory (2)
- TM Forum (2)
- Text Analytics (2)
- Ventilation System (2)
- Virtuelle Realität (2)
- Water (2)
- Water distribution system (2)
- autonomous driving (2)
- eTOM (2)
- enhanced Telecom Operations Map (eTOM) (2)
- mathematical optimization (2)
- robotic process automation (2)
- 197m/gHg (1)
- 3-D printing (1)
- 3D object detection (1)
- Accuracy (1)
- Advanced driver assistance systems (ADAS/AD) (1)
- Agile development (1)
- Agility (1)
- Android (1)
- Angle Sensor (1)
- Anomalieerkennung (1)
- Anomaly detection (1)
- Antennen (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Artificial Intelligence (1)
- Automated driving (1)
- Automation (1)
- Automotive application (1)
- Awareness (1)
- BEV (1)
- BIM (1)
- Benchmark (1)
- Besetzungsinversion (1)
- Bewertungsframework (1)
- Bloom’s Taxonomy (1)
- Booster Stations (1)
- Buffering Capacity (1)
- Building Automation (1)
- Business Engineering (1)
- Business Process (1)
- Bändermodell (1)
- CAV (1)
- CCD-Bildwandler (1)
- CDG (1)
- CMS (1)
- CO2 (1)
- Calcium oxides (1)
- Carbon Dioxide (1)
- Cardiovascular Magnetic Resonance (1)
- Case Study (1)
- Case study (1)
- Chance Constraint (1)
- Change culture (1)
- Chaostheorie (1)
- Charging stations (1)
- Chatbots (1)
- Circuit simulation (1)
- Competence Developing Gam (1)
- Competence Developing Game (1)
- Computational modeling (1)
- Connected Automated Vehicle (1)
- Conpot (1)
- Control (1)
- Control engineering (1)
- Controller Parameter (1)
- Cooling system (1)
- Cryptographic protocols (1)
- Customer Experience Management (1)
- Customer Journeys (1)
- Customer Orientation (1)
- Cyber-physical systems (1)
- Cybersecurity (1)
- Cybersicherheit (1)
- DC machines (1)
- Data analysis (1)
- Data visualization (1)
- Datasets (1)
- Deep learning (1)
- Design Science Research (1)
- DiggiTwin (1)
- Digital Age (1)
- Digital Game Based Learning (1)
- Digital Twin Evolution (1)
- Digital transformation (1)
- Digital triage (1)
- Digital twin (1)
- Digitale Lehre (1)
- Discrete Optimisation (1)
- Dreidimensionale Bildverarbeitung (1)
- Drinking Water Supply (1)
- E-Learning (1)
- E-carsharing (1)
- E-mobility (1)
- EBSCO Discovery Service (1)
- EGG (1)
- Efficiency (1)
- Efficiency optimization (1)
- Electrocardiography (1)
- Electron-phonon coupling (1)
- Electronic learning (1)
- Elektrische Leitung (1)
- Elektronengas (1)
- Elektrotechnik (1)
- Elicit (1)
- Energy (1)
- Energy Disaggregation (1)
- Engineering Application (1)
- Engineering optimisation (1)
- Enhanced Telecom Operations Map (1)
- Enterprise architecture (1)
- Enterprise transformation (1)
- FPGA (1)
- Feldsimulation (1)
- Festkörper (1)
- Forschung (1)
- Forschungsinformationssystem (1)
- Frequency Doubler (1)
- Fully connected car (1)
- Furnace (1)
- Fusion (1)
- Future Skills (1)
- GPU (1)
- Game-based learning (1)
- Gearbox (1)
- Geschäftsmodelle (1)
- Geschäftsprozessmanagement (1)
- Gleichspannungswandler (1)
- Global optimization (1)
- Gold nanoparticle (AuNP) (1)
- Graduiertentagung (1)
- Graph Theory (1)
- HDTV (1)
- Harmonic Radar (1)
- He-Ne Laser (1)
- He-Ne Schema (1)
- Helium-Neon-Laser (1)
- Heuristic algorithms (1)
- High Definition Media Services (1)
- High Quality Streaming (1)
- High field MRI (1)
- Hochfrequenztechnik (1)
- Home Assistant (1)
- Home Automation Platform (1)
- IBM Watson Explorer (1)
- ICS (1)
- IP-based networks (1)
- ISO 26262 (1)
- IT security education (1)
- IT-Marketing (1)
- IT-Sicherheit (1)
- Image Database (1)
- Image Forensics (1)
- Image Quality Assessment (1)
- Image Quality Score (1)
- Implementation Case (1)
- Impulstechnik (1)
- Incremental Encoder (1)
- IndraMotion (1)
- Inductive charging (1)
- Industrial optimisation (1)
- Information and communication technology (1)
- Informationsgetriebene Geschäftsmodelle (1)
- Informationssicherheit (1)
- Informationssicherheitsmanagement (1)
- Integrated mobility (1)
- Intelligentes Parken (1)
- Interactive process mining (1)
- Interdisciplinarity (1)
- Internet der Dinge (1)
- Interval Time Series (1)
- IoT (1)
- Keyword analysis (1)
- Klassifikator <Informatik> (1)
- Kommerzielle Interaktionen (1)
- LQR (1)
- Larynx position (1)
- Latin Hypercube Sampling (1)
- Leaderboard (1)
- Lean thinking (1)
- Level Control System (1)
- Li7La3Zr2O12 (1)
- LiDAR (1)
- LiGaO2 (1)
- Lichtabsorption (1)
- Lichtbetrachtung (1)
- Lichtemission (1)
- Lichtquelle (1)
- Lidar (1)
- Literatur-analyse-prozess (1)
- Literaturdaten (1)
- Literature review (1)
- Literaturrecherche (1)
- Low voltage (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- MILP (1)
- MPC (1)
- MPEG 4 (1)
- MPEG 7 (1)
- MPEG-Standard (1)
- MR safety (1)
- MRI (1)
- Machine learning (1)
- Magneto alert sensor (1)
- Malicious model (1)
- Management (1)
- Manifolds (1)
- Map (eTOM) Process reference model Process design Telecommunications industry (1)
- Matlab (1)
- McLuhan, Marshall (1)
- Meitner-Auger-electron (MAE) (1)
- Methodology (1)
- Minimum Risk Manoeuvre (1)
- Mixed Integer Programming (1)
- Mixed-Integer Nonlinear Optimisation (1)
- Mixed-integer nonlinear black-box optimization (1)
- Mixed-integer nonlinear problem (1)
- Mixed-integer nonlinear programming (1)
- Mixed-integer programming (1)
- Mobile Phones (1)
- Mobility management (1)
- Mode converter (1)
- Modeling (1)
- Monetarisierung (1)
- Monitoring (1)
- Motion-Logic System (1)
- Mpc (1)
- Multi-criteria optimization (1)
- Multimedia-Dienst (1)
- NGN (1)
- Navigation (1)
- Network (1)
- Network design (1)
- Neural networks (1)
- Next Generation Network (1)
- OR 2019 (1)
- Objective data (1)
- Objekterkennung (1)
- Online services (1)
- Open Educational Resources (OER) (1)
- Open Source (1)
- Operational Design Domain (1)
- Optimal Closed Loop (1)
- PPO (1)
- Paper recycling (1)
- Path-following (1)
- Pendel (1)
- Performance (1)
- Personality (1)
- Phonons (1)
- Piecewise Linearization (1)
- Piecewise linearization (1)
- Plasma (1)
- Plasma diagnostics (1)
- Plasmatechnik (1)
- Player Types (1)
- Position Encoder (1)
- Power dissipation (1)
- Praxisprojekte (1)
- Preface (1)
- Privacy-enhancing technologies (1)
- Process design (1)
- Process optimization (1)
- Process reference model (1)
- Process virtualization (1)
- Product bundling (1)
- Product family optimization (1)
- Projektbeispiele (1)
- Prototype (1)
- Prozessabläufe (1)
- Prozessagilität (1)
- Prozessmodellierung (1)
- Prozessstandardisierung (1)
- Pulselektroniklabor (1)
- Pumping systems (1)
- Qualitative Wertschöpfungsanalyse (1)
- Quality control (1)
- Quantum Computing (1)
- Quantum Machine Learning (1)
- Radar (1)
- Reference Process Model (1)
- Reference modelling (1)
- Referenzmodelle (1)
- Reinforcement Learning (1)
- Relaxation (1)
- Rescue System (1)
- Research process (1)
- Resilience (1)
- Resilience Assessment (1)
- Resilience assessment (1)
- Resilience metric graph theory (1)
- Resilient infrastructure (1)
- Resonator (1)
- RoboCup (1)
- Robotic process automation (1)
- Rotary encoder (1)
- Rotational Encoder (1)
- Rotatory Inverted Pendulum (1)
- SPS (1)
- Safety of the intended functionality (SOTIF) (1)
- Safety-critical systems validation (1)
- Secure multi-party computation (1)
- Self-driving (1)
- Sensors comparison (1)
- Serious Games (1)
- Serviceintegration (1)
- Services (1)
- Signalquelle (1)
- Similarity Theory (1)
- Society (1)
- Software (1)
- Software Robots (1)
- Software development (1)
- Software packages (1)
- Software testing (1)
- Softwareroboter (1)
- Solver Per- formance (1)
- Sound Pressure Level (1)
- Speicherprogrammierte Steuerung (1)
- Stochastic Programming (1)
- Story (1)
- Stress testing (1)
- Subject-oriented Business Process Management (1)
- Supraleitung (1)
- Sustainability (1)
- Synchronous machines (1)
- System Design (1)
- System Design Problem (1)
- TGA (1)
- Tag (1)
- Targeted radionuclide therapy (TRT) (1)
- Teamwork (1)
- Technical Operation Research (1)
- Telecommunication Industry (1)
- Telecommunications Industry. (1)
- Text Analytics (1)
- Text Mining (1)
- Text analytics (1)
- Text mining (1)
- Three-dimensional displays (1)
- Throughput (1)
- Time-series synchronization (1)
- Tomography (1)
- Training (1)
- Transdisciplinarity (1)
- Transfer impedance (1)
- Transformation (1)
- Transformation Project (1)
- Transformative Competencies (1)
- Transiton of Control (1)
- Transponder (1)
- Triage-app (1)
- Uktrahigh field MRI (1)
- Uncertainty (1)
- Unternehmensarchitektur (1)
- Unternehmensarchitekturen (1)
- Unternehmensarchitekturen Internet der Dinge (1)
- Unternehmensstrukturen (1)
- Unternehmenstransformation (1)
- Urban areas (1)
- V2X (1)
- VOP compression (1)
- Validation (1)
- Video Game (1)
- Voice assessment (1)
- Vorverarbeitung (1)
- WLTP (1)
- Water Distribution (1)
- Water Supply Networks (1)
- Water Supply System (1)
- Water supply system (1)
- Wearable electronic device (1)
- Wertschöpfungskettenanalyse (1)
- WiLMo (1)
- Wiegand Effect (1)
- Wiegand sensor (1)
- Wirtschaftsinformatik (1)
- Wissenstransfer (1)
- Wärmeübertragung (1)
- Zero-knowledge proofs (1)
- active learning (1)
- agile (1)
- anticipation strategy (1)
- applications (1)
- artificial intelligence (1)
- automated vehicles (1)
- availability (1)
- batteries and fuel cells (1)
- body imaging at 7 T MRI (1)
- body imaging at UHF MRI (1)
- business analytics (1)
- business process automation (1)
- business simulation (1)
- commercial offthe- shelf solutions (1)
- competence developing games (1)
- connected automated vehicles (1)
- culpability (1)
- cybersecurity (1)
- decision analytics (1)
- design of technical systems (1)
- digital economy (1)
- do-it-yourself (1)
- education (1)
- electrospinning (1)
- embedded hardware (1)
- energy efficiency (1)
- energy transfer (1)
- experimental evaluation (1)
- fault detection (1)
- fibers (1)
- ga-doping (1)
- garnet solid electrolyte (1)
- genetic algorithm (1)
- global optimization (1)
- harmonic radar (1)
- harmonic radar tags (1)
- heating system (1)
- honeynet (1)
- honeypot (1)
- ignition (1)
- information systems (1)
- integrated transmit coil arrays (1)
- irradiation (1)
- lab work (1)
- learning theories (1)
- legal obligations (1)
- liability (1)
- management (1)
- metrological characterization (1)
- microplasma (1)
- microwave (MW) plasma (1)
- microwave measurements (1)
- mixed-integer linear programming (1)
- model-predictive control (1)
- motivation theories (1)
- next generation network (1)
- nonlinear VNA measurements (1)
- optimization (1)
- passive inter-modulation (1)
- plasma jet (1)
- porous materials (1)
- power integrity (1)
- product bundling (1)
- product liability (1)
- professional skills (1)
- programming (1)
- remote sensing (1)
- requirements (1)
- research framework (1)
- resilience (1)
- sensor networks (1)
- signal integrity (1)
- slum classification (1)
- software engineering (1)
- software evaluation (1)
- software selection (1)
- solid-state battery (1)
- stochastic optimization (1)
- sustainability (1)
- system optimization (1)
- system synthesis (1)
- systematic literature review (1)
- tablet game (1)
- technical operations research (1)
- technology (1)
- telecommunication (1)
- thermal dose (1)
- tissue temperature (1)
- transmit antenna arrays (1)
- water supply design (1)
- water supply system (1)
- Überwachung & Optimierung (1)
Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used.
With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.
We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation.
This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered.
The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques.
The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx.
Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance.
The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders.
Objectives
Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T.
Methods
A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated.
Results
All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm.
Conclusions
This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.
Background
To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms.
Results
ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.
Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34).
Conclusions
The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.
Objective
The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments.
Methods
MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR.
Results
The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated.
Conclusions
MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.