Refine
Year of publication
Document Type
- Article (608)
- Conference Proceeding (259)
- Book (125)
- Part of a Book (83)
- Doctoral Thesis (10)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
- Contribution to a Periodical (1)
- Master's Thesis (1)
- Poster (1)
Language
- English (579)
- German (522)
- Multiple languages (1)
- nld (1)
- Spanish (1)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Elektromagnetischer Schutzschild (3)
- Hybrid energy system (3)
- INODIS (3)
- Lightning (3)
- Out-of-plane load (3)
- Risikoabschätzung (3)
- Risk management (3)
- Seismic loading (3)
- Stahlbetonkonstruktion (3)
Institute
- Fachbereich Energietechnik (1104) (remove)
Within the framework of the project a genderand diversity-oriented teaching evaluation and modern, media-supported blended learning approaches were used in order to achieve the intended goals. First research results of the literature and status quo analysis were already implemented and tested in newly designed teaching approaches, for example in a multidisciplinary introductory lecture of civil engineering at RWTH Aachen University.
Evaluation of fragility curves for a three-storey-reinforced-concrete mock-up of SMART 2013 project
(2016)
A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.
The performance and biomass yield of the perennial energy plant Sida hermaphrodita (hereafter referred to as Sida) as a feedstock for biogas and solid fuel was evaluated throughout one entire growing period at agricultural field conditions. A Sida plant development code was established to allow comparison of the plant growth stages and biomass composition. Four scenarios were evaluated to determine the use of Sida biomass with regard to plant development and harvest time: (i) one harvest for solid fuel only; (ii) one harvest for biogas production only; (iii) one harvest for biogas production, followed by a harvest of the regrown biomass for solid fuel; and (iv) two consecutive harvests for biogas production. To determine Sida's value as a feedstock for combustion, we assessed the caloric value, the ash quality, and melting point with regard to DIN EN ISO norms. The results showed highest total dry biomass yields of max. 25 t ha⁻¹, whereas the highest dry matter of 70% to 80% was obtained at the end of the growing period. Scenario (i) clearly indicated the highest energy recovery, accounting for 439 288 MJ ha⁻¹; the energy recovery of the four scenarios from highest to lowest followed this order: (i) ≫ (iii) ≫ (iv) > (ii). Analysis of the Sida ashes showed a high melting point of >1500 °C, associated with a net calorific value of 16.5–17.2 MJ kg⁻¹. All prerequisites for DIN EN ISO norms were achieved, indicating Sida's advantage as a solid energy carrier without any post-treatment after harvesting. Cell wall analysis of the stems showed a constant lignin content after sampling week 16 (July), whereas cellulose had already reached a plateau in sampling week 4 (April). The results highlight Sida as a promising woody, perennial plant, providing biomass for flexible and multipurpose energy applications.
In Anbetracht weltweit zunehmend strengerer klimapolitischer
Ziele steigt auch der Druck für Nutzfahrzeughersteller, effizientere und umweltfreundlichere
Technologien zu entwickeln. Den Blick bei der Bewertung dieser
ausschließlich auf die Fahrzeugnutzung zu richten, ist längst nicht mehr zufriedenstellend.
Im Rahmen dieser Analyse wird ein gegenwärtig auf dem Markt erwerblicher
und in deutschen Städten bereits seit Jahren betriebener Hybridbus
energetisch und ökologisch mit einem konventionell angetriebenen, nahezu baugleichen
Modell entlang des Lebensweges bewertet.
Nach Definition von Ziel und Untersuchungsrahmen wird ein Überblick auf bereits
durchgeführte Lebenszyklusanalysen zu Hybridbussen im Stadtverkehr gegeben
und Schlussfolgerungen für die anschließende Analyse abgeleitet. Diese
wird im Rahmen einer energetischen und ökologischen Bewertung beider Produktsysteme
anhand der Parameter "Primärenergieeinsatz" und "CO2äq Emissionen"
praktiziert. Der Fahrzeugrumpf beider Fahrzeuge des gleichen Modells
wird dabei als einheitlich angenommen, sodass bei dem Vergleich der Herstellung
vereinfacht nur die sich unterscheidenden Komponenten des Antriebstranges
berücksichtigt werden. Die Resultate der Wirkungsabschätzung werden als
Differenz des Hybridbusses gegenüber dem Referenzfahrzeug über die einzelnen
Lebenszyklusphasen dargestellt. Schließlich werden Prognosen getroffen, ab
welcher Strecke die bei der Herstellung erzeugten höheren CO2äq Emissionen
des Hybridantriebstranges gegenüber dem Referenzmodell ausgeglichen werden.
Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet.