Refine
Year of publication
- 2017 (60) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (60) (remove)
Has Fulltext
- no (60) (remove)
Language
- English (60) (remove)
Document Type
- Article (41)
- Conference Proceeding (15)
- Part of a Book (3)
- Other (1)
Keywords
- Biomolecular logic gate (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
- DNA (1)
- Dehydrogenase (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme logic gate (1)
- Field-effect sensor (1)
- Gold nanoparticle (1)
- Hotelling’s T² test (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Resonance-mode measurement (1)
- Simultaneous determination (1)
- XOR (1)
- annealing (1)
- complete block symmetry (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- hydroxylation (1)
- likelihood ratio test (1)
- surface functionalization (1)
- uniformly most powerful invariant test (1)
Is part of the Bibliography
- no (60)
Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse
(2017)
Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species
(2017)
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.
The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors.