Refine
Year of publication
Document Type
- Conference Proceeding (77)
- Article (44)
- Lecture (2)
Language
- English (123) (remove)
Has Fulltext
- yes (123) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- FEM (6)
- Clusterion (5)
- shakedown analysis (5)
- Air purification (4)
- Hämoglobin (4)
- Limit analysis (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown analysis (4)
- Einspielanalyse (3)
- Kohlenstofffaser (3)
- Lipopolysaccharide (3)
- Shakedown (3)
- Sonde (3)
- Technische Mechanik (3)
- Traglastanalyse (3)
- limit analysis (3)
- lipopolysaccharides (3)
- shakedown (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Bruchmechanik (2)
- Capacitive field-effect sensor (2)
- Einspiel-Analyse (2)
- Eisschicht (2)
- Erythrozyt (2)
- Fibroblast (2)
- Label-free detection (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Stickstoffmonoxid (2)
- Traglast (2)
- biosensor (2)
- biosensors (2)
- capacitive field-effect sensors (2)
- celldrum technology (2)
- limit load (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- plant scanner (2)
- ratchetting (2)
- 3-nitrofluoranthene (1)
- Adsorption (1)
- Alternating plasticity (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Architectural design (1)
- Autofluoreszenzverfahren (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- BTEX compounds (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Bioreaktor (1)
- Biosensorik (1)
- Blitzschutz (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- CAD ; (1)
- CO (1)
- Carbon sources (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Conducing polymer (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- Dattel (1)
- Deformation (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- ECT (1)
- ELISA (1)
- EPN (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- Fault approximation (1)
- Fault detection (1)
- Fehlerstellen (1)
- Festkörper (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Fluorescence (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Geriatric (1)
- German (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Grenzwertberechnung (1)
- Gunn diode (1)
- Harnleiter (1)
- Heavy metal detection (1)
- Hemoglobin structure (1)
- High throughput experimentation (1)
- Hip fractures (1)
- Hotplate (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- Hämoglobinstruktur (1)
- I3S 2005 (1)
- ISFET (1)
- Information extraction (1)
- International Symposium on Sensor Science (1)
- Inverse scattering problem (1)
- Kinematics (1)
- Kinetics (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Körpertemperatur (1)
- LED chip (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- MCDA (1)
- MEMS (1)
- Main sensitivity (1)
- Materialermüdung (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Medusomyces gisevi (1)
- Microreactors (1)
- Model-driven software engineering (1)
- Multi-dimensional wave propagation (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organkultur (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Phenylalanine determination (1)
- Plant virus (1)
- Plastizität (1)
- Polylactide acid (1)
- Potentiometry (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Random variable (1)
- Ratcheting (1)
- Ratchetting (1)
- Reaction-diffusion (1)
- Red blood cell storage (1)
- Resistive temperature detector (1)
- Rohr (1)
- Rohrbruch (1)
- Schwammknochen (1)
- Sensitivity (1)
- Sepsis (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Software and systems modeling (1)
- Solid amalgam electrodes (1)
- Stahl (1)
- Statics (1)
- Strukturanalyse (1)
- Supraleiter (1)
- Temperaturabhängigkeit (1)
- Tendons (1)
- Tin oxide (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- UML (1)
- Ultrasound (1)
- Unified Modeling Language (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alcoholic beverages (1)
- alternierend Verformbarkeit (1)
- ammonia gas sensors (1)
- amperometric biosensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- aromatic amines (1)
- atomic layer deposition (1)
- autofluorescence-based detection system (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- carbonized rice husk (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- direct method (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- ecological structure (1)
- elastic solids (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- encapsulation materials (1)
- enzymatic biosensor (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- epithelization (1)
- fatigue analyses (1)
- fenitrothion (1)
- fibroin (1)
- finite element analysis (1)
- flaw (1)
- fluidic (1)
- fortschreitende plastische Deformation (1)
- gas sensor (1)
- gas sensor array (1)
- glucose (1)
- graphene oxide (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- human dermal fibroblasts (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- large language models (1)
- layer expansion (1)
- layer-by-layer technique (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load limit (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metagenomics (1)
- metal oxide (1)
- microbial diversity (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanomaterials (1)
- naphtols (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH sensors (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- penicillin (1)
- penicillinase (1)
- phenols (1)
- photoelectrochemistry (1)
- pipes (1)
- plant stress (1)
- plasma generated ions (1)
- polyaniline (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- reliability (1)
- reliability analysis (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- semantic role labeling (1)
- sensing properties (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- speaker attribution (1)
- sterilisation (1)
- sterility tests (1)
- sterilization efficacy (1)
- sterilization methods (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- tension–torsion loading (1)
- thermal ratcheting (1)
- thick-film technology (1)
- thin-film microsensors (1)
- titanium dioxide photoanode (1)
- ultrathin gate insulators (1)
- validation methods (1)
- vessels (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (123) (remove)
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.
This paper reports a first microbial biosensor for rapid and cost-effective determination of organophosphorus pesticides fenitrothion and EPN. The biosensor consisted of recombinant PNP-degrading/oxidizing bacteria Pseudomonas putida JS444 anchoring and displaying organophosphorus hydrolase (OPH) on its cell surface as biological sensing element and a dissolved oxygen electrode as the transducer. Surfaceexpressed OPH catalyzed the hydrolysis of fenitrothion and EPN to release 3-methyl-4-nitrophenol and p-nitrophenol, respectively, which were oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen, which was measured and correlated to the concentration of organophosphates. Under the optimum operating conditions, the biosensor was able to measure as low as 277 ppb of fenitrothion and 1.6 ppm of EPN without interference from phenolic compounds and other commonly used pesticides such as carbamate pesticides, triazine herbicides and organophosphate pesticides without nitrophenyl substituent. The applicability of the biosensor to lake water was also demonstrated.
This paper presents a two-dimensional-in-space mathematical model of biosensors based on an array of enzyme microreactors immobilised on a single electrode. The modeling system acts under amperometric conditions. The microreactors were modeled by particles and by strips. The model is based on the diffusion equations containing a nonlinear term related to the Michaelis-Menten kinetics of the enzymatic reaction. The model involves three regions: an array of enzyme microreactors where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration is maintained constant. Using computer simulation, the influence of the geometry of the microreactors and of the diffusion region on the biosensor response was investigated. The digital simulation was carried out using the finite difference technique.
The applicability of differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) at a non-toxic meniscus-modified silver solid amalgam electrode (m-AgSAE) for the determination of trace amounts of genotoxic substances was demonstrated on the determination of micromolar and submicromolar concentrations of 3-nitrofluoranthene using methanol - 0.01 mol L-1 NaOH (9:1) mixture as a base electrolyte and of Ostazine Orange using 0.01 mol L-1 NaOH as a base electrolyte.
Novel organic membrane-based thin-film microsensors for the determination of heavy metal cations
(2006)
A first step towards the fabrication and electrochemical evaluation of thin-film microsensors based on organic PVC membranes for the determination of Hg(II), Cd(II), Pb(II) and Cu(II) ions in solutions has been realised. The membrane-coating mixture used in the preparation of this new type of microsensors is incorporating PVC as supporting matrix, o-nitrophenyloctylether (o-NPOE) as solvent mediator and a recently synthesized Hg[dimethylglyoxime(phene)]2+ and Bis-(4-hydroxyacetophenone)-ethylenediamine as electroactive materials for Hg(II) and Cd(II), respectively. A set of three commercialised ionophores for Cd(II), Pb(II) and Cu(II) has been also used for comparison. Thin-film microsensors based on these membranes showed a Nernstian response of slope (26-30 mV/dec.) for the respective tested cations. The potentiometric response characteristics (linear range, pH range, detection limit and response time) are comparable with those obtained by conventional membranes as well as coated wire electrodes prepared from the same membrane. The realisation of the new organic membrane-based thin-film microsensors overcomes the problem of an insufficient selectivity of solid-state-based thinfilm sensors.
In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration.
Hydrophobic magnetic nanoparticles (NPs) consisting of undecanoate-capped magnetite (Fe3O4, average diameter ca. 5 nm) are used to control quantized electron transfer to surface-confined redox units and metal NPs. A two-phase system consisting of an aqueous electrolyte solution and a toluene phase that includes the suspended undecanoatecapped magnetic NPs is used to control the interfacial properties of the electrode surface. The attracted magnetic NPs form a hydrophobic layer on the electrode surface resulting in the change of the mechanisms of the surface-confined electrochemical processes. A quinone-monolayer modified Au electrode demonstrates an aqueous-type of the electrochemical process (2e-+2H+ redox mechanism) for the quinone units in the absence of the hydrophobic magnetic NPs, while the attraction of the magnetic NPs to the surface results in the stepwise single-electron transfer mechanism characteristic of a dry nonaqueous medium. Also, the attraction of the hydrophobic magnetic NPs to the Au electrode surface modified with Au NPs (ca. 1.4 nm) yields a microenvironment with a low dielectric constant that results in the single-electron quantum charging of the Au NPs.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.