Refine
Year of publication
- 2022 (48) (remove)
Document Type
- Article (32)
- Conference Proceeding (7)
- Book (4)
- Part of a Book (3)
- Other (1)
- Report (1)
Keywords
- Biocomposites (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
- Stress concentrations (2)
- damage (2)
- Alzheimer's disease (1)
- Biomechanical simulation (1)
- Bootstrapping (1)
- Categorial variable (1)
- Cementoblast (1)
- Chance constrained programming (1)
- Clustering (1)
- Collective risk model (1)
- Compression (1)
- Concomitant (1)
- Deep Learning (1)
- ES-FEM (1)
- Elektroenzephalographie (1)
- Empirical process (1)
- Evolution of damage (1)
- Extension fracture (1)
- Extension strain criterion (1)
- FGF23 (1)
- FS-FEM (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Haemodialysis (1)
- Handbike (1)
- Heterostructure (1)
- Image Reconstruction (1)
- Independence test (1)
- Information Extraction (1)
- Klotho (1)
- Limit analysis (1)
- Machine learning (1)
- Mechanotransduction (1)
- Metascintillator (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Mohr–Coulomb criterion (1)
- Multiple TOF kernels (1)
- Myocardial infarction and cardiac death (1)
- Natural Language Processing (1)
- Niacin (1)
- PTH (1)
- Paralympic sport (1)
- Phosphate (1)
- Profile Extraction (1)
- Proximal humerus fracture (1)
- Psychiatrische Biomarker (1)
- Pulsations (1)
- Reliability of structures (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Riboflavin (1)
- Rotator cuff (1)
- S-FEM (1)
- Schlafspindeldetektion (1)
- Shakedown analysis (1)
- Stochastic programming (1)
- TOF PET (1)
- Tension (1)
- Text Mining (1)
- Thiamine (1)
- Tobacco mosaic virus (1)
- Vasomotions (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- acetoin (1)
- adipose-derived stromal cells (ASCs) (1)
- anaesthetic complications (1)
- anisotropy (1)
- aortic perfusion (1)
- atomic layer deposition (1)
- biaxial tensile experiment (1)
- biocompatible materials (1)
- biodegradable electronic devices (1)
- biopotential electrodes (1)
- biosensors (1)
- bootstrap (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- cognitive impairment (1)
- computational fluid dynamics analysis (1)
- constitutive modeling (1)
- correlation (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- endoluminal (1)
- enzyme immobilization (1)
- extracorporeal membrane oxygenation (1)
- force generation (1)
- forehead EEG (1)
- glucose (1)
- high-intensity exercise (1)
- hyperelastic (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- limit analysis (1)
- muscle fascicle behavior (1)
- non-simplex S-FEM elements (1)
- pH sensors (1)
- performance testing (1)
- reliability of structures (1)
- retinal vessels (1)
- sEMG (1)
- shakedown analysis (1)
- simulation (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- survival (1)
- tendon rupture (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasound imaging (1)
- ultrathin gate insulators (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking gait (1)
- · Psychiatrische Erkrankungen/Diagnostik (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (48) (remove)
Reliable methods for automatic readability assessment have the potential to impact a variety of fields, ranging from machine translation to self-informed learning. Recently, large language models for the German language (such as GBERT and GPT-2-Wechsel) have become available, allowing to develop Deep Learning based approaches that promise to further improve automatic readability assessment. In this contribution, we studied the ability of ensembles of fine-tuned GBERT and GPT-2-Wechsel models to reliably predict the readability of German sentences. We combined these models with linguistic features and investigated the dependence of prediction performance on ensemble size and composition. Mixed ensembles of GBERT and GPT-2-Wechsel performed better than ensembles of the same size consisting of only GBERT or GPT-2-Wechsel models. Our models were evaluated in the GermEval 2022 Shared Task on Text Complexity Assessment on data of German sentences. On out-of-sample data, our best ensemble achieved a root mean squared error of 0:435.
Biocompatibility, flexibility and durability make polydimethylsiloxane (PDMS) membranes top candidates in biomedical applications. CellDrum technology uses large area, <10 µm thin membranes as mechanical stress sensors of thin cell layers. For this to be successful, the properties (thickness, temperature, dust, wrinkles, etc.) must be precisely controlled. The following parameters of membrane fabrication by means of the Floating-on-Water (FoW) method were investigated: (1) PDMS volume, (2) ambient temperature, (3) membrane deflection and (4) membrane mechanical compliance. Significant differences were found between all PDMS volumes and thicknesses tested (p < 0.01). They also differed from the calculated values. At room temperatures between 22 and 26 °C, significant differences in average thickness values were found, as well as a continuous decrease in thicknesses within a 4 °C temperature elevation. No correlation was found between the membrane thickness groups (between 3–4 µm) in terms of deflection and compliance. We successfully present a fabrication method for thin bio-functionalized membranes in conjunction with a four-step quality management system. The results highlight the importance of tight regulation of production parameters through quality control. The use of membranes described here could also become the basis for material testing on thin, viscous layers such as polymers, dyes and adhesives, which goes far beyond biological applications.
This study aims to quantify the kinematics, kinetics and muscular activity of all-out handcycling exercise and examine their alterations during the course of a 15-s sprint test. Twelve able-bodied competitive triathletes performed a 15-s all-out sprint test in a recumbent racing handcycle that was attached to an ergometer. During the sprint test, tangential crank kinetics, 3D joint kinematics and muscular activity of 10 muscles of the upper extremity and trunk were examined using a power metre, motion capturing and surface electromyography (sEMG), respectively. Parameters were compared between revolution one (R1), revolution two (R2), the average of revolution 3 to 13 (R3) and the average of the remaining revolutions (R4). Shoulder abduction and internal-rotation increased, whereas maximal shoulder retroversion decreased during the sprint. Except for the wrist angles, angular velocity increased for every joint of the upper extremity. Several muscles demonstrated an increase in muscular activation, an earlier onset of muscular activation in crank cycle and an increased range of activation. During the course of a 15-s all-out sprint test in handcycling, the shoulder muscles and the muscles associated to the push phase demonstrate indications for short-duration fatigue. These findings are helpful to prevent injuries and improve performance in all-out handcycling.
It was generally believed that coal sources are not favorable as live-in habitats for microorganisms due to their recalcitrant chemical nature and negligible decomposition. However, accumulating evidence has revealed the presence of diverse microbial groups in coal environments and their significant metabolic role in coal biogeochemical dynamics and ecosystem functioning. The high oxygen content, organic fractions, and lignin-like structures of lower-rank coals may provide effective means for microbial attack, still representing a greatly unexplored frontier in microbiology. Coal degradation/conversion technology by native bacterial and fungal species has great potential in agricultural development, chemical industry production, and environmental rehabilitation. Furthermore, native microalgal species can offer a sustainable energy source and an excellent bioremediation strategy applicable to coal spill/seam waters. Additionally, the measures of the fate of the microbial community would serve as an indicator of restoration progress on post-coal-mining sites. This review puts forward a comprehensive vision of coal biodegradation and bioprocessing by microorganisms native to coal environments for determining their biotechnological potential and possible applications.
Objective
Hemodialysis patients show an approximately threefold higher prevalence of cognitive impairment compared to the age-matched general population. Impaired microcirculatory function is one of the assumed causes. Dynamic retinal vessel analysis is a quantitative method for measuring neurovascular coupling and microvascular endothelial function. We hypothesize that cognitive impairment is associated with altered microcirculation of retinal vessels.
Methods
152 chronic hemodialysis patients underwent cognitive testing using the Montreal Cognitive Assessment. Retinal microcirculation was assessed by Dynamic Retinal Vessel Analysis, which carries out an examination recording retinal vessels' reaction to a flicker light stimulus under standardized conditions.
Results
In unadjusted as well as in adjusted linear regression analyses a significant association between the visuospatial executive function domain score of the Montreal Cognitive Assessment and the maximum arteriolar dilation as response of retinal arterioles to the flicker light stimulation was obtained.
Conclusion
This is the first study determining retinal microvascular function as surrogate for cerebral microvascular function and cognition in hemodialysis patients. The relationship between impairment in executive function and reduced arteriolar reaction to flicker light stimulation supports the involvement of cerebral small vessel disease as contributing factor for the development of cognitive impairment in this patient population and might be a target for noninvasive disease monitoring and therapeutic intervention.
Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions.
Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch.
Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume.
Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.
Cell spraying has become a feasible application method for cell therapy and tissue engineering approaches. Different devices have been used with varying success. Often, twin-fluid atomizers are used, which require a high gas velocity for optimal aerosolization characteristics. To decrease the amount and velocity of required air, a custom-made atomizer was designed based on the effervescent principle. Different designs were evaluated regarding spray characteristics and their influence on human adipose-derived mesenchymal stromal cells. The arithmetic mean diameters of the droplets were 15.4–33.5 µm with decreasing diameters for increasing gas-to-liquid ratios. The survival rate was >90% of the control for the lowest gas-to-liquid ratio. For higher ratios, cell survival decreased to approximately 50%. Further experiments were performed with the design, which had shown the highest survival rates. After seven days, no significant differences in metabolic activity were observed. The apoptosis rates were not influenced by aerosolization, while high gas-to-liquid ratios caused increased necrosis levels. Tri-lineage differentiation potential into adipocytes, chondrocytes, and osteoblasts was not negatively influenced by aerosolization. Thus, the effervescent aerosolization principle was proven suitable for cell applications requiring reduced amounts of supplied air. This is the first time an effervescent atomizer was used for cell processing.
On the basis of independent and identically distributed bivariate random vectors, where the components are categorial and continuous variables, respectively, the related concomitants, also called induced order statistic, are considered. The main theoretical result is a functional central limit theorem for the empirical process of the concomitants in a triangular array setting. A natural application is hypothesis testing. An independence test and a two-sample test are investigated in detail. The fairly general setting enables limit results under local alternatives and bootstrap samples. For the comparison with existing tests from the literature simulation studies are conducted. The empirical results obtained confirm the theoretical findings.