Refine
Year of publication
- 2019 (71) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (71) (remove)
Document Type
- Article (53)
- Conference Proceeding (11)
- Book (2)
- Doctoral Thesis (2)
- Part of a Book (1)
- Patent (1)
- Talk (1)
Keywords
- Achilles tendon (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Automatic control (1)
- Force (1)
- Goodness-of-fit test (1)
- Human-Computer interaction (1)
- Iterative learning control (1)
- Knee (1)
- Load modeling (1)
Is part of the Bibliography
- no (71)
Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application
(2019)
Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich).
The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool.
Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement
(2019)
System und Verfahren zur Durchführung von Messungen biaxialer und kreuzförmiger Zugversuche, wobei ein Weg oder eine Kraft auf eine Materialprobe über mindestens zwei Nadelarme mit Nadeln geleitet wird, die in einem Gehäuse gelagert sind, wobei die Arme und/oder Nadelarme für eine ungehinderte Querkontraktion bei gleichmäßiger Lasteinleitung um eine Achse drehbar gelagert und seitlich auslenkbar sind.