Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (533) (remove)
Has Fulltext
- no (533) (remove)
Language
- English (533) (remove)
Document Type
- Article (485)
- Conference Proceeding (33)
- Part of a Book (8)
- Doctoral Thesis (3)
- Book (2)
- Other (2)
Keywords
- frequency mixing magnetic detection (4)
- LAPS (3)
- Light-addressable potentiometric sensor (3)
- capacitive field-effect sensor (3)
- field-effect sensor (3)
- magnetic nanoparticles (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Calorimetric gas sensor (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- biosensors (2)
- gold nanoparticles (2)
- hydrogen peroxide (2)
- light-addressable potentiometric sensor (2)
- microfluidics (2)
- (Bio)degradation (1)
- Alginate beads (1)
- Bacillus atrophaeus spores (1)
- CNOT (1)
- CRISPR/Cas9 (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA biosensor (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Extracellular enzymes (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Field-effect sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Hypersecretion (1)
- Impedance spectroscopy (1)
- Lab-on-Chip (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- MOS (1)
- Marker-free mutagenesis (1)
- Multi-sensor system (1)
- Multianalyte detection (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Potentiometry (1)
- Real-time monitoring (1)
- Resonance-mode measurement (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Uracil-phosphoribosyltransferase (1)
- XOR (1)
- acetoin (1)
- actuator-sensor system (1)
- aminooctanethiol (1)
- annealing (1)
- aquaculture (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- aspergillus (1)
- bi-enzyme biosensor (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive field-effect biosensor (1)
- capacitive model (1)
- catalytic metal (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- colorization (1)
- control gate (1)
- coupled Néel–Brownian relaxation dynamics (1)
- detection of charged macromolecules (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- endospores (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- field-effect structure (1)
- filamentous fungi (1)
- frequency mixing (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- genome engineering (1)
- glucose oxidase (GOx) (1)
- heavy metals (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- impedance spectroscopy (1)
- key performance indicators (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic sensors (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- metal-oxide-semiconductor structure (1)
- micromagnetic simulation (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- multiparametric immunoassays (1)
- multiplex detection (1)
- nanobelts (1)
- nanoparticle coverage (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- penicillinase (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- polystyrene sulfonate (1)
- scanned light pulse technique (1)
- silanization (1)
- spore kill rate (1)
- sterilisation (1)
- sterility (1)
- sterilization (1)
- sterilization conditions (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- temperature (1)
- thermometry (1)
- turnip vein clearing virus (TVCV) (1)
- urease (1)
- visualization (1)
LAPS are field-effect-based potentiometric sensors which are able to monitor analyte concentrations in a spatially resolved manner. Hence, a LAPS sensor system is a powerful device to record chemical imaging of the concentration of chemical species in an aqueous solution, chemical reactions, or the growth of cell colonies on the sensor surface, to record chemical images. In this work, multi-chamber 3D-printed structures made out of polymer (PP-ABS) were combined with LAPS chips to analyse differentially and simultaneously the metabolic activity of Escherichia coli K12 and Chinese hamster ovary (CHO) cells, and the responds of those cells to the addition of glucose solution.
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.
In this work, a sensor to evaluate sterilization processes with hydrogen peroxide vapor has been characterized. Experimental, analytical and numerical methods were applied to evaluate and study the sensor behavior. The sensor set-up is based on planar interdigitated electrodes. The interdigitated electrode structure consists of 614 electrode fingers spanning over a total sensing area of 20 mm2. Sensor measurements were conducted with and without microbiological spores as well as after an industrial sterilization protocol. The measurements were verified using an analytical expression based on a first-order elliptical integral. A model based on the finite element method with periodic boundary conditions in two dimensions was developed and utilized to validate the experimental findings.
The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed.
The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed.
In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor.