Article
Refine
Year of publication
Document Type
- Article (112) (remove)
Language
- English (112) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- shakedown analysis (3)
- Einspielanalyse (2)
- Shakedown analysis (2)
- Traglastanalyse (2)
- damage (2)
- limit analysis (2)
- shakedown (2)
- Alternating plasticity (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biocomposites (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Convex optimization (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Discontinuous fractures (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- ES-FEM (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- FS-FEM (1)
- Fehlerstellen (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Global and local collapse (1)
- Grenzwertberechnung (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Limit analysis (1)
- Liver (1)
- Materialermüdung (1)
- Natural fibres (1)
- Non-parallel fissures (1)
- Pharmacology (1)
- Plastizität (1)
- Polymer-matrix composites (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Ratchetting (1)
- Rohr (1)
- Rohrbruch (1)
- S-FEM (1)
- Schwammknochen (1)
- Shakedown (1)
- Shakedown criterion (1)
- Spleen (1)
- Stahl (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- Surgical staplers (1)
- Temperaturabhängigkeit (1)
- Traglast (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Zug-Druck Belastung (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- difficult airway (1)
- direct method (1)
- distorted element (1)
- double-lumen tube intubation (1)
- elastic solids (1)
- fatigue analyses (1)
- flaw (1)
- fortschreitende plastische Deformation (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- konvexe Optimierung (1)
- limit load (1)
- load limit (1)
- non-simplex S-FEM elements (1)
- pipes (1)
- ratchetting (1)
- reliability analysis (1)
- reliability of structures (1)
- shakedown analyses (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- tension–torsion loading (1)
- thermal ratcheting (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- yield stress (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (112) (remove)
Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential.
Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue.
While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint.
Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.
Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis.
Determination of the frictional coefficient of the implant-antler interface : experimental approach
(2012)
The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.