Refine
Year of publication
- 2024 (26)
- 2023 (40)
- 2022 (52)
- 2021 (56)
- 2020 (59)
- 2019 (71)
- 2018 (68)
- 2017 (67)
- 2016 (54)
- 2015 (70)
- 2014 (66)
- 2013 (65)
- 2012 (72)
- 2011 (82)
- 2010 (73)
- 2009 (85)
- 2008 (61)
- 2007 (57)
- 2006 (75)
- 2005 (48)
- 2004 (85)
- 2003 (57)
- 2002 (55)
- 2001 (54)
- 2000 (65)
- 1999 (40)
- 1998 (39)
- 1997 (36)
- 1996 (32)
- 1995 (19)
- 1994 (13)
- 1993 (19)
- 1992 (13)
- 1991 (12)
- 1990 (17)
- 1989 (21)
- 1988 (22)
- 1987 (26)
- 1986 (7)
- 1985 (10)
- 1984 (9)
- 1983 (6)
- 1982 (24)
- 1981 (16)
- 1980 (30)
- 1979 (20)
- 1978 (27)
- 1977 (13)
- 1976 (16)
- 1975 (14)
- 1974 (4)
- 1973 (3)
- 1972 (6)
- 1971 (1)
- 1969 (1)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2082) (remove)
Document Type
- Article (1596)
- Conference Proceeding (243)
- Book (97)
- Part of a Book (62)
- Doctoral Thesis (28)
- Patent (17)
- Report (15)
- Other (9)
- Habilitation (4)
- Lecture (3)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web
(2012)
The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.