Refine
Year of publication
- 2024 (22)
- 2023 (38)
- 2022 (51)
- 2021 (56)
- 2020 (59)
- 2019 (70)
- 2018 (68)
- 2017 (67)
- 2016 (54)
- 2015 (70)
- 2014 (65)
- 2013 (65)
- 2012 (72)
- 2011 (82)
- 2010 (72)
- 2009 (85)
- 2008 (61)
- 2007 (57)
- 2006 (75)
- 2005 (48)
- 2004 (85)
- 2003 (57)
- 2002 (55)
- 2001 (54)
- 2000 (65)
- 1999 (40)
- 1998 (39)
- 1997 (36)
- 1996 (32)
- 1995 (19)
- 1994 (13)
- 1993 (19)
- 1992 (13)
- 1991 (12)
- 1990 (17)
- 1989 (21)
- 1988 (22)
- 1987 (26)
- 1986 (7)
- 1985 (10)
- 1984 (9)
- 1983 (6)
- 1982 (24)
- 1981 (16)
- 1980 (30)
- 1979 (20)
- 1978 (27)
- 1977 (13)
- 1976 (16)
- 1975 (14)
- 1974 (4)
- 1973 (3)
- 1972 (6)
- 1971 (1)
- 1969 (1)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2072) (remove)
Document Type
- Article (1591)
- Conference Proceeding (241)
- Book (96)
- Part of a Book (62)
- Doctoral Thesis (27)
- Patent (17)
- Report (15)
- Other (9)
- Habilitation (4)
- Lecture (3)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
Einschränkung von Taluskippung und -vorschub durch Sprunggelenkorthesen nach fibularer Bandruptur
(2013)
Die fibulare Bandruptur zählt zu einer der am häufigsten auftretenden Verletzungen des
Bewegungsapparats. In den meisten Fällen wird heute die konservativ frühfunktionelle Therapie mit Sprunggelenkorthesen allgemein bevorzugt. Im Rahmen der vorliegenden Studie wurden 14 verschiedene Sprunggelenkorthesen im Hinblick auf ihre Einschränkung von Taluskippung und Talusvorschub
untersucht. Zur Simulation einer fibularen Bandruptur wurde ein Unterschenkelmodell aus Holz mit Fußteil, mit angelegten Orthesen in einen Scheuba-Halteapparat eingespannt und mit 150 N seitlich sowie anterior-posterior belastet. Anhand der erstellten "gehaltenen" Röntgenaufnahmen konnten Taluskippung und Talusvorschub jeder einzelnen Orthese eindeutig bestimmt werden. Die meisten Orthesen erreichten zufriedenstellende Ergebnisse. Es stellte sich heraus, dass vor allem eine eng anliegende, im Gelenkbereich anatomisch angepasste Form vorteilhaft zu sein scheint.
A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions
(2019)
Based on the European Space Agency (ESA) Science in Space Environment (SciSpacE) community White Paper “Human Physiology – Musculoskeletal system”, this perspective highlights unmet needs and suggests new avenues for future studies in musculoskeletal research to enable crewed exploration missions. The musculoskeletal system is essential for sustaining physical function and energy metabolism, and the maintenance of health during exploration missions, and consequently mission success, will be tightly linked to musculoskeletal function. Data collection from current space missions from pre-, during-, and post-flight periods would provide important information to understand and ultimately offset musculoskeletal alterations during long-term spaceflight. In addition, understanding the kinetics of the different components of the musculoskeletal system in parallel with a detailed description of the molecular mechanisms driving these alterations appears to be the best approach to address potential musculoskeletal problems that future exploratory-mission crew will face. These research efforts should be accompanied by technical advances in molecular and phenotypic monitoring tools to provide in-flight real-time feedback.
It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.