Refine
Year of publication
- 2017 (262) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- IfB - Institut für Bioengineering (34)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Energietechnik (27)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Bauingenieurwesen (14)
- Fachbereich Architektur (13)
Document Type
- Article (109)
- Conference Proceeding (87)
- Part of a Book (34)
- Book (14)
- Other (11)
- Part of a Periodical (2)
- Report (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Patent (1)
Keywords
- Autonomous mobile robots (2)
- Gamification (2)
- Industry 4.0 (2)
- MASCOT (2)
- Multi-robot systems (2)
- Smart factory (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Ausfachungsmauerwerk (1)
- Automated Optimization (1)
Is part of the Bibliography
- no (262)
A high-Q resonance-mode measurement of EIS capacitive sensor by elimination of series resistance
(2017)
An EIS capacitive sensor is a semiconductor-based potentiometric sensor, which is sensitive to the ion concentration or pH value of the solution in contact with the sensing surface. To detect a small change in the ion concentration or pH, a small capacitance change must be detected. Recently, a resonance-mode measurement was proposed, in which an inductor was connected to the EIS capacitive sensor and the resonant frequency was correlated with the pH value. In this study, the Q factor of the resonant circuit was enhanced by canceling the internal resistance of the reference electrode and the internal resistance of the inductor coil with the help of a bypass capacitor and a negative impedance converter, respectively. 1% variation of the signal in the developed system corresponded to a pH change of 3.93 mpH, which was about 1/12 of the conventional method, suggesting a better performance in detection of a small pH change.
Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology
(2017)
The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor.