Refine
Year of publication
- 2013 (301) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- Fachbereich Elektrotechnik und Informationstechnik (43)
- INB - Institut für Nano- und Biotechnologien (40)
- Fachbereich Energietechnik (36)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (29)
- Fachbereich Luft- und Raumfahrttechnik (26)
- Fachbereich Bauingenieurwesen (17)
- Fachbereich Maschinenbau und Mechatronik (15)
- FH Aachen (11)
- Fachbereich Architektur (8)
- Solar-Institut Jülich (7)
- Fachbereich Gestaltung (6)
- Sonstiges (6)
- Nowum-Energy (4)
- ECSM European Center for Sustainable Mobility (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
Document Type
- Article (139)
- Conference Proceeding (77)
- Part of a Book (25)
- Book (24)
- Part of a Periodical (12)
- Report (9)
- Doctoral Thesis (5)
- Patent (4)
- Other (2)
- Conference: Meeting Abstract (1)
Keywords
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.
Wing weight estimation methodology for highly non-planar lifting systems during conceptual design
(2013)
Unsere unternehmerische Umwelt befindet sich in einem zunehmend dynamischen Wandel. Dies führt dazu, dass Herausforderungen, denen sich Unternehmen stellen müssen, immer komplexer werden. Hier gilt es zunehmend, eine Balance zwischen verschiedenen Spannungsfeldern zu erreichen. Sogenannte Megatrends stellen die Treiber dieses Wandels dar. Als Megatrend werden nach dem Zukunftsinstitut (2010a) richtungsweisende Veränderungstendenzen aufgefasst, die alle Bereiche des Lebens sowohl individuell als auch gesellschaftlich beeinflussen und langfristige Auswirkungen haben.