Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1695)
- Fachbereich Elektrotechnik und Informationstechnik (719)
- IfB - Institut für Bioengineering (626)
- Fachbereich Energietechnik (589)
- INB - Institut für Nano- und Biotechnologien (557)
- Fachbereich Chemie und Biotechnologie (553)
- Fachbereich Luft- und Raumfahrttechnik (497)
- Fachbereich Maschinenbau und Mechatronik (284)
- Fachbereich Wirtschaftswissenschaften (222)
- Solar-Institut Jülich (165)
Language
- English (4939) (remove)
Document Type
- Article (3288)
- Conference Proceeding (1171)
- Part of a Book (195)
- Book (146)
- Doctoral Thesis (32)
- Conference: Meeting Abstract (29)
- Patent (25)
- Other (10)
- Report (10)
- Conference Poster (6)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients.