Wissenschaftlicher Artikel
Filtern
Erscheinungsjahr
- 2013 (139) (entfernen)
Institut
- Fachbereich Medizintechnik und Technomathematik (49)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Chemie und Biotechnologie (24)
- IfB - Institut für Bioengineering (21)
- Fachbereich Wirtschaftswissenschaften (18)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Energietechnik (12)
- Sonstiges (6)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Fachbereich Bauingenieurwesen (4)
Dokumenttyp
- Wissenschaftlicher Artikel (139) (entfernen)
Schlagworte
- Bacillus atrophaeus (1)
- Distorsion des oberen Sprunggelenks (1)
- Epithel (1)
- Fibroblast (1)
- Prozessabläufe (1)
- Prozessmodellierung (1)
- Prozessstandardisierung (1)
- Referenzmodellierung (1)
- Sprunggelenkorthesen (1)
- Wundheilung (1)
- ankle braces (1)
- ankle sprain (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- carbonized rice husk (1)
- eTOM (1)
- epithelization (1)
- fibulare Bandruptur (1)
- human dermal fibroblasts (1)
- hydrogen peroxide (1)
- rupture of the fibular ligament (1)
- sterilisation (1)
- wound healing (1)
Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.
Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Aluminiumverbundguss-Stahlblech-Hybriden am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich untersucht.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen
zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding
GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler
Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Stahlblech-AluminiumverbundgussHybriden
am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich
untersucht.