Article
Refine
Year of publication
Document Type
- Article (104) (remove)
Keywords
- Einspielen <Werkstoff> (3)
- damage (2)
- shakedown analysis (2)
- Alternating plasticity (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Arthosetherapie (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Biocomposites (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Drug simulation (1)
- ES-FEM (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- FEM (1)
- FS-FEM (1)
- Fehlerstellen (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Finite-Elemente-Methode (1)
- Fließgrenze (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Limit analysis (1)
- Liver (1)
- MBST (1)
- Natural fibres (1)
- Non-parallel fissures (1)
- Pharmacology (1)
- Plastizität (1)
- Polymer-matrix composites (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Ratchetting (1)
- Rohr (1)
- Rohrbruch (1)
- S-FEM (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Shakedown (1)
- Shakedown analysis (1)
- Shakedown criterion (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stahl (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- Surgical staplers (1)
- Temperaturabhängigkeit (1)
- Traglastanalyse (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Zug-Druck Belastung (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- arthrosis therapy (1)
- biaxial tensile experiment (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- cancellous bone (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- fibulare Bandruptur (1)
- flaw (1)
- fortschreitende plastische Deformation (1)
- gonarthrosis (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- limit analysis (1)
- load limit (1)
- non-simplex S-FEM elements (1)
- pipes (1)
- ratchetting (1)
- reliability of structures (1)
- rupture of the fibular ligament (1)
- shakedown (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- tension–torsion loading (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- yield stress (1)
Institute
- IfB - Institut für Bioengineering (104) (remove)
Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment