Refine
Year of publication
- 2014 (43) (remove)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (43) (remove)
Document Type
- Article (13)
- Conference Proceeding (13)
- Report (6)
- Book (4)
- Part of a Book (3)
- Other (2)
- Video (1)
- Patent (1)
Keywords
Mein Freund, die Uni
(2014)
Objectives
To assess the image quality of T2-weighted (T2w) magnetic resonance imaging of the prostate and the visibility of prostate cancer at 7 Tesla (T).
Materials & methods
Seventeen prostate cancer patients underwent T2w imaging at 7T with only an external transmit/receive array coil. Three radiologists independently scored images for image quality, visibility of anatomical structures, and presence of artefacts. Krippendorff’s alpha and weighted kappa statistics were used to assess inter-observer agreement. Visibility of prostate cancer lesions was assessed by directly linking the T2w images to the confirmed location of prostate cancer on histopathology.
Results
T2w imaging at 7T was achievable with ‘satisfactory’ (3/5) to ‘good’ (4/5) quality. Visibility of anatomical structures was predominantly scored as ‘satisfactory’ (3/5) and ‘good’ (4/5). If artefacts were present, they were mostly motion artefacts and, to a lesser extent, aliasing artefacts and noise. Krippendorff’s analysis revealed an α = 0.44 between three readers for the overall image quality scores. Clinically significant cancer lesions in both peripheral zone and transition zone were visible at 7T.
Conclusion
T2w imaging with satisfactory to good quality can be routinely acquired, and cancer lesions were visible in patients with prostate cancer at 7T using only an external transmit/receive body array coil.
Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers
(2014)
Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role.
Die Informationsbroschüre „3D-Druck – Prozessmanagement für individualisierte Massenprodukte“ richtet sich an 3D-Druckdienstleister, die additive Fertigungsverfahren (Additive Manufacturing) nutzen, sowie an IT-Dienstleister, die eine Plattform für den Datenaustausch und die Individualisierung anbieten.
Mit der additiven 3D-Drucktechnologie erfolgt die Fertigung von Produkten durch einen schichtweisen Aufbau. In dieser Broschüre werden mögliche Potenziale im Bereich der Herstellung mittels additiver Fertigungsverfahren aufgezeigt.
Die Informationsbroschüre „Anforderungen an die Gestaltung multimodaler Mobilitätsanwendungen“ richtet sich an IT-Dienstleister. In dieser Broschüre werden mögliche Potenziale im Bereich des allgemeinen Mobilitätsmanagements aufgezeigt. Automobilhersteller vernetzten sich zunehmend mit Technologie-Unternehmen. Es geht nicht nur um die besondere Entwicklung von spezieller Elektronik- und Softwarelösungen für Navigations- und Entertainmentsysteme oder auch Fahrassistenz-Systemen in modernen PKW, sondern um einen übergreifenden Design- und Interaktionsansatz für miteinander vernetzte Geräte.