Refine
Year of publication
- 2024 (56)
- 2023 (117)
- 2022 (147)
- 2021 (154)
- 2020 (172)
- 2019 (198)
- 2018 (173)
- 2017 (155)
- 2016 (161)
- 2015 (176)
- 2014 (167)
- 2013 (174)
- 2012 (164)
- 2011 (189)
- 2010 (187)
- 2009 (189)
- 2008 (157)
- 2007 (149)
- 2006 (160)
- 2005 (130)
- 2004 (161)
- 2003 (106)
- 2002 (130)
- 2001 (106)
- 2000 (108)
- 1999 (109)
- 1998 (99)
- 1997 (99)
- 1996 (81)
- 1995 (78)
- 1994 (87)
- 1993 (59)
- 1992 (54)
- 1991 (29)
- 1990 (39)
- 1989 (45)
- 1988 (57)
- 1987 (32)
- 1986 (19)
- 1985 (34)
- 1984 (22)
- 1983 (20)
- 1982 (29)
- 1981 (20)
- 1980 (36)
- 1979 (24)
- 1978 (34)
- 1977 (14)
- 1976 (13)
- 1975 (12)
- 1974 (3)
- 1973 (2)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1695)
- Fachbereich Elektrotechnik und Informationstechnik (719)
- IfB - Institut für Bioengineering (626)
- Fachbereich Energietechnik (589)
- INB - Institut für Nano- und Biotechnologien (557)
- Fachbereich Chemie und Biotechnologie (553)
- Fachbereich Luft- und Raumfahrttechnik (498)
- Fachbereich Maschinenbau und Mechatronik (284)
- Fachbereich Wirtschaftswissenschaften (222)
- Solar-Institut Jülich (165)
Language
- English (4940) (remove)
Document Type
- Article (3264)
- Conference Proceeding (1191)
- Part of a Book (196)
- Book (146)
- Conference: Meeting Abstract (33)
- Doctoral Thesis (32)
- Patent (25)
- Other (10)
- Report (10)
- Conference Poster (6)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Gamification (6)
- Limit analysis (6)
While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates.
The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 Ã 20 Ã 10 mm3 monolithic LSO crystal block.
Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.
Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
Manufacturing Process Simulation for the Prediction of Tool-Part-Interaction and Ply Wrinkling
(2019)