Refine
Year of publication
Document Type
- Article (608)
- Conference Proceeding (259)
- Book (125)
- Part of a Book (83)
- Doctoral Thesis (10)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
- Contribution to a Periodical (1)
- Master's Thesis (1)
- Poster (1)
Language
- English (579)
- German (522)
- Multiple languages (1)
- nld (1)
- Spanish (1)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Elektromagnetischer Schutzschild (3)
- Hybrid energy system (3)
- INODIS (3)
- Lightning (3)
- Out-of-plane load (3)
- Risikoabschätzung (3)
- Risk management (3)
- Seismic loading (3)
- Stahlbetonkonstruktion (3)
- earthquakes (3)
- renewable energy (3)
- Adjacent buildings (2)
- Central receiver power plant (2)
- Concentrated systems (2)
- Direkter Blitzschlag (2)
- Diversity (2)
- Electricity generation (2)
- Energierecht (2)
- Engineering Habitus (2)
- Erneuerbare Energien (2)
- Gas turbine (2)
- Gasturbine (2)
- Historical centres (2)
- Human-robot collaboration (2)
- Hybridsystem (2)
- INSYSME (2)
- Induzierte Spannungen (2)
- Innovation Management (2)
- Lightning Protection (2)
- Lightning protection system (2)
- Magnetische Felder (2)
- Masonry infill (2)
- Micro turbine (2)
- Mikrogasturbine (2)
- Organizational Culture (2)
- Regenerative Energieanlagen (2)
- Renewable energy (2)
- Risikoabwägung (2)
- Risk assessment (2)
- Shake table test (2)
- Solar thermal technologies (2)
- Stone masonry (2)
- Tanks (2)
- cyber physical production system (2)
- digital shadow (2)
- electromagnetic shielding (2)
- engineering education (2)
- hybrid system (2)
- industrial facilities (2)
- installations (2)
- photovoltaic system (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- wind turbine (2)
- Academia (1)
- Acceptance (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alternative Energiequelle (1)
- Anti-Bias (1)
- Antibias (1)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Best practice sharing (1)
- Biogas (1)
- Blind prediction competition (1)
- Blitz (1)
- Blitzeinschlag (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Bloom Taxonomy (1)
- COMSOL Multiphysics (1)
- Camera system (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Central receiver system (1)
- Ceramics (1)
- Change Management (1)
- Change management (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- Cloud passages (1)
- Cognitive assistance system (1)
- Components (1)
- Concentrated solar collector (1)
- Concentrating solar power (1)
- Control optimization (1)
- Corporate Culture (1)
- DIN EN 1996 (1)
- DNI forecast (1)
- DNI forecasting (1)
- Decision theory (1)
- Decoupling (1)
- Design Thinking (1)
- Design examples (1)
- Digital leadership (1)
- Digitalization (1)
- Direct lightning strike (1)
- Direct normal irradiance forecast (1)
- District data model (1)
- District energy planning platform (1)
- Diversity management (1)
- Dynamic simulation (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Electrochemistry (1)
- Elektrizität (1)
- Elektromagnetische Kopplung (1)
- Emilia-Romagna earthquake (1)
- Emissionshandel (1)
- Emissionsrechtehandel (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Energiekonzept (1)
- Energietechnik (1)
- Energietechnische Anlage (1)
- Energy (1)
- Energy Systems (1)
- Energy system (1)
- Energy system planning (1)
- Engineering (1)
- Engineering Education (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Erneuerbares Energiengesetz (1)
- Ethics (1)
- Eurocode 8 (1)
- Fernerkundung (1)
- Feuchtigkeit (1)
- Fracture classification (1)
- Frame structure (1)
- Fresnel power plant (1)
- Future Skills (1)
- Future skills (1)
- Gas (1)
- Gender (1)
- Genetic algorithm (1)
- Gesamtwassergehalt (1)
- Global change (1)
- Gust wind response (1)
- Heliostat Field Calibration (1)
- Heliostats (1)
- Higher Education (1)
- Hilbert Room (1)
- Human factors (1)
- Human-centered work design (1)
- Hybridanlage (1)
- Hybridization (1)
- Imaging (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Inclusive work climate (1)
- Industrial facilities (1)
- Industrial units (1)
- Industrieanlagen (1)
- Infill wall design (1)
- Infrarot-Reflexions-Absorptions-Spektroskopie (1)
- Infrarotmesstechnik (1)
- Innovation (1)
- Interaction (1)
- Interculturality (1)
- Interdisciplinarity (1)
- Isolation (1)
- Kalkulation (1)
- Kernenergie (1)
- Key competences (1)
- Kraftwerke (1)
- Leadership (1)
- Left ventriular function (1)
- Lightning Risk (1)
- Linear elastic analysis (1)
- LiveLink for MATLAB (1)
- MIR-Spektroskopie (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Maßstabsgetreues Modell (1)
- Measuring instruments (1)
- Methane (1)
- Mixed integer linear programming (MILP) (1)
- Modern constructions (1)
- Molten salt receiver (1)
- Molten salt receiver system (1)
- Molten salt receiver system, (1)
- Molten salt solar tower (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Nowcasting (1)
- Nuclear Applications (1)
- Numerical modelling (1)
- Operators (1)
- Optimization module (1)
- Organizational culture (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- PTC (1)
- Parabolic trough collector (1)
- Perception (1)
- Photovoltaics (1)
- Photovoltaikanlage (1)
- Photovoltaikanlagen (1)
- Piping (1)
- Postulates (1)
- Power conversion systems (1)
- Precast buildings (1)
- Privacy (1)
- Probability distribution mapping (1)
- Process prediction (1)
- Psychological concepts (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- Pyrometrie (1)
- Quadrocopter (1)
- Quantenkaskadenlaser (1)
- Quantenmechanik (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Renewable energy integration (1)
- Response spectrum (1)
- Responsibility (1)
- Risiko (1)
- Risk (1)
- Risk Assessment (1)
- Risk Management (1)
- Risk assessment ; Insurance (1)
- Schrödingers cat (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Shoulder (1)
- Silos (1)
- Slab deflection (1)
- Social impact measurement (1)
- Solar concentration (1)
- Solar dish (1)
- Solar irradiance (1)
- Speckle (1)
- Spectral analysis (1)
- Stahlbeton (1)
- Stahlbetonrahmen (1)
- Star design (1)
- Structural design (1)
- Structural health monitoring (1)
- Sustainability (1)
- Sustainable engineering education (1)
- Tank (1)
- Temperaturmessung (1)
- Thermal Energy Storage (1)
- Time-series aggregation (1)
- Transient flux distribution (1)
- Trinitrotol (1)
- Two-phase modelling (1)
- Typical periods (1)
- UAV (1)
- Umwelt (1)
- Umweltzertifikathandel (1)
- Uncertainty analysis (1)
- Unmanned aerial vehicle (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verdunstungskälte (1)
- Verhaltensbeiwerte (1)
- Versicherung (1)
- Virtuelle Kraftwerke (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wind turbulence (1)
- Windenergieanlage (1)
- Windenergieanlagen (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- acoustic pyrometry (1)
- behaviour factor q (1)
- best practice (1)
- bio-methane (1)
- body limbs (1)
- bubble column (1)
- bullying (1)
- calculations (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- change management (1)
- churches (1)
- concentrating collector (1)
- connection detail (1)
- current distribution (1)
- cyber-physical production system (1)
- deserts (1)
- digital twin (1)
- digitalization (1)
- dissemination (1)
- distribution grid simulation (1)
- diversity (1)
- diversity management (1)
- down-conductor (1)
- e-mobility (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- education (1)
- elastomeric bearing (1)
- electrocardiogram (1)
- electromagnetic coupling (1)
- electromagnetic shield (1)
- energy concept (1)
- energy transition (1)
- engineering (1)
- environment (1)
- equivalent stiffness (1)
- finite element method (1)
- flue gas components (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- gender and diversity (1)
- granular silo (1)
- high field MR imaging (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hybrid-system (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- induced voltage (1)
- induced voltages (1)
- innovation (1)
- innovation management (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- internet of production (1)
- lessons learned (1)
- lightning flash (1)
- lightning protection (1)
- lightning strike (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic field (1)
- magnetic fields (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- metal façade (1)
- methanation (1)
- modern constructions (1)
- nonlinear transient analyses (1)
- open educational resources (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- overvoltages (1)
- phonocardiogram (1)
- plug flow reactor (1)
- point-focussing system (1)
- policy recommendations (1)
- power-to-gas (1)
- protection measures (1)
- raytracing (1)
- recommendations for actions (1)
- renewable energies (1)
- research association (1)
- risk assessment (1)
- risk management (1)
- safety control (1)
- scaled model (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- smart-charging (1)
- social responsible engineering (1)
- solar process heat (1)
- steam production (1)
- steel columns (1)
- storage dispatch (1)
- storage optimisation (1)
- structure-soil-structure interaction (1)
- swimming (1)
- teaching (1)
- temperature measurement (1)
- thermal storage (1)
- touch voltage (1)
- truss (1)
- unreinforced masonry buildings (1)
- user & usage (1)
- vault (1)
- vocal fold oscillation (1)
- Überspannung (1)
Institute
- Fachbereich Energietechnik (1104) (remove)
Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta
(2001)
Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind.
Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden.