Article
Refine
Year of publication
Institute
- Fachbereich Chemie und Biotechnologie (602) (remove)
Document Type
- Article (602) (remove)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biotechnological application (2)
- Butanol (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- Subtilases (2)
- Subtilisin (2)
- bubble column (2)
- methanation (2)
- plug flow reactor (2)
- qNMR (2)
- (Poly)saccharides (1)
- ABE (1)
- Acid crash (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alginate beads (1)
- Alkalihalobacillus okhensis (1)
- Aloe vera (1)
- Authenticity (1)
- Biofuel (1)
- Biogas (1)
- Biological hydrogen (1)
- Biomass (1)
- Biorefinery (1)
- Bragg peak (1)
- Broad pH spectrum (1)
- C. acetobutylicum (1)
- CRISPR/Cas9 (1)
- Carrier solvents (1)
- Chondroitin sulfate (1)
- Circular bioeconomy (1)
- Clostridium acetobutylicum (1)
- Crude heparin (1)
- Cyclotron production (1)
- Dark fermentation (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Dietary supplements (1)
- Electronic cigarettes (1)
- Enzymatic biosensor (1)
- Extracellular enzymes (1)
- Free-base nicotine (1)
- Ga-68 (1)
- Glucosamine (1)
- Halotolerant protease (1)
- High-field NMR (1)
- Hydrolysis (1)
- Hypersecretion (1)
- IR (1)
- Inorganic ions (1)
- Ions (1)
- Lignocellulose (1)
- Linear discriminant analysis (1)
- Low field NMR (1)
- Manufacturer (1)
- Marker-free mutagenesis (1)
- Medical radionuclide production (1)
- Metabolic shift (1)
- Metal contaminants (1)
- Methane (1)
- Microfluidic solvent extraction (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- NMR (1)
- Organic acids (1)
- Organic waste (1)
- P2G (1)
- PLS-regression (1)
- Polysaccharides (1)
- Pre-culture (1)
- Pretreatment (1)
- Quality control (1)
- Quantum chemistry (1)
- Simultaneous determination (1)
- Soft independent modeling of class analogy (1)
- Spectroscopy (1)
- Stenotrophomonas maltophilia (1)
- Streptomyces griseus (1)
- Streptomyces lividans (1)
- USP (1)
- Uracil-phosphoribosyltransferase (1)
- Weak organic acids (1)
- acetoin (1)
- acetoin reductase (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- aspergillus (1)
- bacterial cellulose (1)
- bi-enzyme biosensor (1)
- bio-methane (1)
- bioavailability (1)
- biodegradable polymers (1)
- biological dosimeter (1)
- biomethane (1)
- biosensors (1)
- borehole disposal (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- coculture (1)
- deficit irrigation (1)
- detergent protease (1)
- disposal facility (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- elastomers (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- exopolysaccharides (1)
- filamentous fungi (1)
- genome engineering (1)
- geological disposal (1)
- glycine (1)
- halotolerant protease (1)
- high-alkaline subtilisin (1)
- human metabolites (1)
- hydrogel (1)
- hydrogels (1)
- light-addressable electrode (1)
- light-addressable potentiometric sensor (1)
- mechanical properties (1)
- microfluidics (1)
- micronutrients (1)
- neutrons (1)
- nuclear waste (1)
- onion (1)
- optical fibers (1)
- oxidative stable protease (1)
- penicillinase (1)
- polyaspartic acid (1)
- power-to-gas (1)
- prebiotic (1)
- proton therapy (1)
- protons (1)
- pullulan (1)
- recombinant expression (1)
- relative dosimetry (1)
- retention time (1)
- rubber (1)
- superabsorbent polymers (1)
- supramolecular structures (1)
- swelling properties (1)
- theory and modeling (1)
- tobacco mosaic virus (TMV) (1)
- transporters (1)
- urease (1)
- water economy (1)
- yield (1)
- α-aminoacylase (1)
- ε-lysine acylase (1)
Investigation of TRPV1 loss-of-function phenotypes in transgenic shRNA expressing and knockout mice
(2008)
The investigation of the possibility to determine various characteristics of powder heparin (n = 115) was carried out with infrared spectroscopy. The evaluation of heparin samples included several parameters such as purity grade, distributing company, animal source as well as heparin species (i.e. Na-heparin, Ca-heparin, and heparinoids). Multivariate analysis using principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), and partial least squares – discriminant analysis (PLS-DA) were applied for the modelling of spectral data. Different pre-processing methods were applied to IR spectral data; multiplicative scatter correction (MSC) was chosen as the most relevant.
Obtained results were confirmed by nuclear magnetic resonance (NMR) spectroscopy. Good predictive ability of this approach demonstrates the potential of IR spectroscopy and chemometrics for screening of heparin quality. This approach, however, is designed as a screening tool and is not considered as a replacement for either of the methods required by USP and FDA.
The molecular weight properties of lignins are one of the key elements that need to be analyzed for a successful industrial application of these promising biopolymers. In this study, the use of 1H NMR as well as diffusion-ordered spectroscopy (DOSY NMR), combined with multivariate regression methods, was investigated for the determination of the molecular weight (Mw and Mn) and the polydispersity of organosolv lignins (n = 53, Miscanthus x giganteus, Paulownia tomentosa, and Silphium perfoliatum). The suitability of the models was demonstrated by cross validation (CV) as well as by an independent validation set of samples from different biomass origins (beech wood and wheat straw). CV errors of ca. 7–9 and 14–16% were achieved for all parameters with the models from the 1H NMR spectra and the DOSY NMR data, respectively. The prediction errors for the validation samples were in a similar range for the partial least squares model from the 1H NMR data and for a multiple linear regression using the DOSY NMR data. The results indicate the usefulness of NMR measurements combined with multivariate regression methods as a potential alternative to more time-consuming methods such as gel permeation chromatography.
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.