Refine
Year of publication
- 2012 (310) (remove)
Document Type
- Article (128)
- Conference Proceeding (89)
- Part of a Book (35)
- Book (26)
- Patent (11)
- Part of Periodical (9)
- Doctoral Thesis (6)
- Report (4)
- Habilitation (1)
- Other (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bio-Sensors (1)
- Biosensor (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Central receiver system (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Compliance (1)
- Concentrated solar collector (1)
- Consensus (1)
- Contractile tension (1)
- Contractility (1)
- C–V method (1)
- Decomposition (1)
- Detergent protease (1)
- Discourse ethics (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Eisschicht (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Energiewirtschaft (1)
- Esophageal Doppler monitor (1)
- Extracellular enzymes (1)
- FH Aachen (1)
- Fachhochschule Aachen (1)
- Field-effect sensor (1)
- Finite differences (1)
- Finite element modelling (1)
- Force (1)
- Forschungsbericht (1)
- Freeze–thaw process (1)
- Fresnel collector (1)
- Fußball (1)
- Gleichspannungswandler (1)
- Graduiertentagung (1)
- Grid Computing (1)
- Guerrillawerbung (1)
- Heat transport (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- IP-based networks (1)
- Impedance spectroscopy (1)
- Individual Investors (1)
- IndraMotion (1)
- Industrial Automation Technology, (1)
- Kinetic energy (1)
- Konsumgesellschaft (1)
- Künstlerisches Handeln (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low-field NMR (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Marker-free mutagenesis (1)
- Medienforschung (1)
- Motion-Logic System (1)
- NGN (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanotechnologie (1)
- Negative Feedback Trading (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Numerical linear algebra (1)
- Optical and thermal analysis (1)
- Organic light-emitting diode display (1)
- Ownership Unbundling (1)
- PIV (1)
- PROFINET (1)
- Parasitäre Strategie (1)
- Politische Kunst (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Research Report (1)
- Robotik (1)
- SLM (1)
- SPS (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Selektives Laser Schmelzen (1)
- Silber (1)
- Snow (1)
- Solar concentration (1)
- Sonde (1)
- Speicherprogrammierte Steuerung (1)
- Spleen (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stromnetz (1)
- Surgical staplers (1)
- Tool support (1)
- Trading Behavior (1)
- Uracil-phosphoribosyltransferase (1)
- VOF (1)
- Variable height stapler design (1)
- Velocity (1)
- Volume status (1)
- Wireless Networks (1)
- Workflow (1)
- Workflow Orchestration (1)
- Wärmeübertragung (1)
- brachytherapy (1)
- dam-break (1)
- drag force (1)
- eigensolvers (1)
- incontinence (1)
- mobile robots (1)
- next generation network (1)
- numerical model (1)
- performance analysis (1)
- physical model (1)
- product bundling (1)
- prostate cancer (1)
- prostatectomy (1)
- quality of life (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- telecommunication (1)
- Übertragungsnetz (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (32)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Chemie und Biotechnologie (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
- Fachbereich Luft- und Raumfahrttechnik (13)
- FH Aachen (12)
- Fachbereich Gestaltung (9)
- Fachbereich Architektur (6)
- Sonstiges (3)
- Freshman Institute (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Nowum-Energy (1)
Electron beam plasma measurement was realised by means of DIABEAM system invented by ISF RWTH Aachen. The Langmuir probe method is used for measurement. The relative simplicity of the method and the possibility of dispersion of high power on the probe allow its application for the investigation of high-power electron beams. The key element of the method is a rotating thin tungsten wire, which intersects the beam transversely on its axis and collects part of the current by itself. The signals, which are registered in the DIABEAM as a voltage, were taken in the form of amplitude. The conversion of the probe current into the distribution along the beam radius was realised using the Abel’s method. A voltage-current characteristic was built for the beam current. The local electron density as well as the electron temperature, the floating potential and the plasma potential were measured and calculated by means of this characteristic.
It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage.
Two types of microvalves based on temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm) and pH-responsive poly(sodium acrylate) (PSA) hydrogel films have been developed and tested. The PNIPAAm and PSA hydrogel films were prepared by means of in situ photopolymerization directly inside the fluidic channel of a microfluidic chip fabricated by combining Si and SU-8 technologies. The swelling/shrinking properties and height changes of the PNIPAAm and PSA films inside the fluidic channel were studied at temperatures of deionized water from 14 to 36 °C and different pH values (pH 3–12) of Titrisol buffer, respectively. Additionally, in separate experiments, the lower critical solution temperature (LCST) of the PNIPAAm hydrogel was investigated by means of a differential scanning calorimetry (DSC) and a surface plasmon resonance (SPR) method. Mass-flow measurements have shown the feasibility of the prepared hydrogel films to work as an on-chip integrated temperature- or pH-responsive microvalve capable to switch the flow channel on/off.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.