Refine
Year of publication
- 2012 (333) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Elektrotechnik und Informationstechnik (41)
- Fachbereich Chemie und Biotechnologie (40)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (31)
- Fachbereich Bauingenieurwesen (30)
- Fachbereich Maschinenbau und Mechatronik (29)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Document Type
- Article (130)
- Conference Proceeding (89)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Part of a Periodical (9)
- Doctoral Thesis (7)
- Report (4)
- Habilitation (1)
Keywords
- Elektromobilität (7)
- Elektrofahrzeug (5)
- Energieversorgungsnetz (5)
- Kraftfahrzeugelektronik (5)
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (2)
- Elektromobilität; Elektrofahrzeug; Energieversorungsnetz; Kraftfahrzeugtechnik (2)
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bio-Sensors (1)
- Biosensor (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Central receiver system (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Compliance (1)
- Concentrated solar collector (1)
- Consensus (1)
- Contractile tension (1)
- Contractility (1)
- C–V method (1)
- Decomposition (1)
- Detergent protease (1)
- Discourse ethics (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Eisschicht (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Energiewirtschaft (1)
- Esophageal Doppler monitor (1)
- Extracellular enzymes (1)
- FH Aachen (1)
- Fachhochschule Aachen (1)
- Field-effect sensor (1)
- Finite differences (1)
- Finite element modelling (1)
- Force (1)
- Forschungsbericht (1)
- Freeze–thaw process (1)
- Fresnel collector (1)
- Fußball (1)
- Gleichspannungswandler (1)
- Graduiertentagung (1)
- Grid Computing (1)
- Guerrillawerbung (1)
- Heat transport (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- IP-based networks (1)
- Impedance spectroscopy (1)
- Individual Investors (1)
- IndraMotion (1)
- Industrial Automation Technology, (1)
- Kinetic energy (1)
- Konsumgesellschaft (1)
- Künstlerisches Handeln (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low-field NMR (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Marker-free mutagenesis (1)
- Medienforschung (1)
- Molkeproteine (1)
- Motion-Logic System (1)
- NGN (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanotechnologie (1)
- Negative Feedback Trading (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Numerical linear algebra (1)
- Optical and thermal analysis (1)
- Organic light-emitting diode display (1)
- Ownership Unbundling (1)
- PIV (1)
- PROFINET (1)
- Parasitäre Strategie (1)
- Politische Kunst (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Requirements prioritization (1)
- Requirements relations (1)
- Research Report (1)
- Robotik (1)
- SLM (1)
- SPS (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Selektives Laser Schmelzen (1)
- Silber (1)
- Snow (1)
- Solar concentration (1)
- Sonde (1)
- Speicherprogrammierte Steuerung (1)
- Spleen (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stromnetz (1)
- Surgical staplers (1)
- Tool support (1)
- Trading Behavior (1)
- Uracil-phosphoribosyltransferase (1)
- VOF (1)
- Variable height stapler design (1)
- Velocity (1)
- Volume status (1)
- Wireless Networks (1)
- Workflow (1)
- Workflow Orchestration (1)
- Wärmeübertragung (1)
- architectural design process (1)
- brachytherapy (1)
- dam-break (1)
- design theory (1)
- drag force (1)
- eigensolvers (1)
- incontinence (1)
- instruments (1)
- interdisciplinarity (1)
- methodologies (1)
- mobile robots (1)
- next generation network (1)
- numerical model (1)
- performance analysis (1)
- physical model (1)
- product bundling (1)
- prostate cancer (1)
- prostatectomy (1)
- quality of life (1)
- subglacial aquatic ecosystems (1)
- subsurface ice (1)
- telecommunication (1)
- Übertragungsnetz (1)
Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.
Bioconjugates containing the GnRH-III hormone decapeptide as a targeting moiety are able to deliver chemotherapeutic agents specifically to cancer cells expressing GnRH receptors, thereby increasing their local efficacy while limiting the peripheral toxicity. However, the number of GnRH receptors on cancer cells is limited and they desensitize under continuous hormone treatment. A possible approach to increase the receptor mediated tumor targeting and consequently the cytostatic effect of the bioconjugates would be the attachment of more than one chemotherapeutic agent to one GnRH-III molecule. Here we report on the design, synthesis and biochemical characterization of multifunctional bioconjugates containing GnRH-III as a targeting moiety and daunorubicin as a chemotherapeutic agent. Two different drug design approaches were pursued. The first one was based on the bifunctional [4Lys]-GnRH-III (Glp-His-Trp-Lys-His-Asp-Trp-Lys-Pro-Gly-NH2) containing two lysine residues in positions 4 and 8, whose ϵ-amino groups were used for the coupling of daunorubicin. In the second drug design, the native GnRH-III (Glp-His-Trp-Ser-His-Asp-Trp-Lys-Pro-Gly-NH2) was used as a scaffold; an additional lysine residue was coupled to the ϵ-amino group of 8Lys in order to generate two free amino groups available for conjugation of daunorubicin. The in vitro stability/degradation of all synthesized compounds was investigated in human serum, as well as in the presence of rat liver lysosomal homogenate. Their cellular uptake was determined on human breast cancer cells and the cytostatic effect was evaluated on human breast, colon and prostate cancer cell lines. Compared with a monofunctional compound, both drug design approaches resulted in multifunctional bioconjugates with increased cytostatic effect.
Purpose:
To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle.
Materials and Methods:
The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization.
Results:
The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs.
Conclusion:
This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc.
Im Beitrag wird zunächst das Verfahren eines dynamischen elektro-geometrischen Modells vorgestellt. Dieses arbeitet im Gegensatz zum klassischen Blitzkugel-Verfahren nicht mit konstanten Radien; vielmehr wird der Radius der Blitzkugel variiert. Dabei werden ausschließlich vorhandene und in internationalen Normen anerkannte Ergebnisse, blitzphysikalische Grundlagen und Untersuchungen verwendet, und auf deren Grundlage ein numerisches Verfahren erarbeitet. Mit dem dynamischen elektro-geometrischen Modell werden dann einige Beispiele des Schutzes mit Fangstangen, die gemäß dem klassischen Blitzkugel-Verfahren nach DIN EN 62305-3 für die Schutzklassen I – II – III – IV geplant sind, untersucht. Es wird gezeigt, dass die Einfangwirksamkeiten wesentlich höher sind als in der Normenreihe DIN EN 62305 selbst angegeben. Grund dafür ist die Tatsache, dass das Blitzkugel-Verfahren sehr konservativ aufgebaut ist und dem Planer von Blitzschutzsystemen nur die möglichen Stellen für einen Einschlag aufzeigt, ohne eine Bewertung der Einschlagshäufigkeit zu liefern. Andererseits bedeutet dies jedoch, dass man mit dem klassischen Blitzkugel-Verfahren stets auf der „sicheren Seite“ liegt.
Determinants of earnings forecast error, earnings forecast revision and earnings forecast accuracy
(2012)
Earnings forecasts are ubiquitous in today’s financial markets. They are essential indicators of future firm performance and a starting point for firm valuation. Extremely inaccurate and overoptimistic forecasts during the most recent financial crisis have raised serious doubts regarding the reliability of such forecasts. This thesis therefore investigates new determinants of forecast errors and accuracy. In addition, new determinants of forecast revisions are examined. More specifically, the thesis answers the following questions: 1) How do analyst incentives lead to forecast errors? 2) How do changes in analyst incentives lead to forecast revisions?, and 3) What factors drive differences in forecast accuracy?
Determination of the frictional coefficient of the implant-antler interface : experimental approach
(2012)
The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.