Article
Refine
Year of publication
- 2024 (34)
- 2023 (66)
- 2022 (79)
- 2021 (86)
- 2020 (102)
- 2019 (95)
- 2018 (85)
- 2017 (72)
- 2016 (79)
- 2015 (83)
- 2014 (93)
- 2013 (97)
- 2012 (82)
- 2011 (130)
- 2010 (122)
- 2009 (121)
- 2008 (103)
- 2007 (94)
- 2006 (86)
- 2005 (99)
- 2004 (131)
- 2003 (74)
- 2002 (92)
- 2001 (88)
- 2000 (84)
- 1999 (88)
- 1998 (82)
- 1997 (79)
- 1996 (70)
- 1995 (68)
- 1994 (77)
- 1993 (51)
- 1992 (48)
- 1991 (25)
- 1990 (35)
- 1989 (38)
- 1988 (54)
- 1987 (32)
- 1986 (18)
- 1985 (32)
- 1984 (18)
- 1983 (17)
- 1982 (26)
- 1981 (18)
- 1980 (35)
- 1979 (23)
- 1978 (30)
- 1977 (14)
- 1976 (13)
- 1975 (10)
- 1974 (3)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1359)
- INB - Institut für Nano- und Biotechnologien (503)
- Fachbereich Chemie und Biotechnologie (473)
- Fachbereich Elektrotechnik und Informationstechnik (414)
- IfB - Institut für Bioengineering (410)
- Fachbereich Energietechnik (361)
- Fachbereich Luft- und Raumfahrttechnik (254)
- Fachbereich Maschinenbau und Mechatronik (151)
- Fachbereich Wirtschaftswissenschaften (116)
- Fachbereich Bauingenieurwesen (69)
Language
- English (3285) (remove)
Document Type
- Article (3285) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- additive manufacturing (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
Often, detailed simulations of heat conduction in complicated, porous media have large runtimes. Then homogenization is a powerful tool to speed up the calculations by preserving accurate solutions at the same time. Unfortunately real structures are generally non-periodic, which requires unpractical, complicated homogenization techniques. We demonstrate in this paper, that the application of simple, periodic techniques to realistic media, that are just close to periodic, gives accurate, approximative solutions. In order to obtain effective parameters for the homogenized heat equation, we have to solve a so called “cell problem”. In contrast to periodic structures it is not trivial to determine a suitable unit cell, which represents a non-periodic media. To overcome this problem, we give a rule of thumb on how to choose a good cell. Finally we demonstrate the efficiency of our method for virtually generated foams as well as real foams and compare these results to periodic structures.
We present a concise mini overview on the approaches to the disposal of nuclear waste currently used or deployed. The disposal of nuclear waste is the end point of nuclear waste management (NWM) activities and is the emplacement of waste in an appropriate facility without the intention to retrieve it. The IAEA has developed an internationally accepted classification scheme based on the end points of NWM, which is used as guidance. Retention times needed for safe isolation of waste radionuclides are estimated based on the radiotoxicity of nuclear waste. Disposal facilities usually rely on a multi-barrier defence system to isolate the waste from the biosphere, which comprises the natural geological barrier and the engineered barrier system. Disposal facilities could be of a trench type, vaults, tunnels, shafts, boreholes, or mined repositories. A graded approach relates the depth of the disposal facilities’ location with the level of hazard. Disposal practices demonstrate the reliability of nuclear waste disposal with minimal expected impacts on the environment and humans.
Malaria infection remains a significant risk for much of the population of tropical and subtropical areas, particularly in developing countries. Therefore, it is of high importance to develop sensitive, accurate and inexpensive malaria diagnosis tests. Here, we present a novel aptamer-based electrochemical biosensor (aptasensor) for malaria detection by impedance spectroscopy, through the specific recognition between a highly discriminatory DNA aptamer and its target Plasmodium falciparum lactate dehydrogenase (PfLDH). Interestingly, due to the isoelectric point (pI) of PfLDH, the aptasensor response showed an adjustable detection range based on the different protein net-charge at variable pH environments. The specific aptamer recognition allows sensitive protein detection with an expanded detection range and a low detection limit, as well as a high specificity for PfLDH compared to analogous proteins. The specific feasibility of the aptasensor is further demonstrated by detection of the target PfLDH in human serum. Furthermore, the aptasensor can be easily regenerated and thus applied for multiple usages. The robustness, sensitivity, and reusability of the presented aptasensor make it a promising candidate for point-of-care diagnostic systems.