Article
Refine
Year of publication
- 2024 (34)
- 2023 (66)
- 2022 (79)
- 2021 (86)
- 2020 (102)
- 2019 (96)
- 2018 (85)
- 2017 (72)
- 2016 (79)
- 2015 (83)
- 2014 (93)
- 2013 (97)
- 2012 (82)
- 2011 (130)
- 2010 (122)
- 2009 (121)
- 2008 (103)
- 2007 (94)
- 2006 (86)
- 2005 (99)
- 2004 (131)
- 2003 (74)
- 2002 (92)
- 2001 (88)
- 2000 (84)
- 1999 (88)
- 1998 (82)
- 1997 (79)
- 1996 (70)
- 1995 (68)
- 1994 (77)
- 1993 (51)
- 1992 (48)
- 1991 (25)
- 1990 (35)
- 1989 (38)
- 1988 (54)
- 1987 (32)
- 1986 (18)
- 1985 (32)
- 1984 (18)
- 1983 (17)
- 1982 (26)
- 1981 (18)
- 1980 (35)
- 1979 (23)
- 1978 (30)
- 1977 (14)
- 1976 (13)
- 1975 (10)
- 1974 (3)
- 1972 (2)
- 1971 (1)
- 1968 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1359)
- INB - Institut für Nano- und Biotechnologien (503)
- Fachbereich Chemie und Biotechnologie (473)
- Fachbereich Elektrotechnik und Informationstechnik (414)
- IfB - Institut für Bioengineering (410)
- Fachbereich Energietechnik (361)
- Fachbereich Luft- und Raumfahrttechnik (254)
- Fachbereich Maschinenbau und Mechatronik (152)
- Fachbereich Wirtschaftswissenschaften (116)
- Fachbereich Bauingenieurwesen (69)
Language
- English (3286) (remove)
Document Type
- Article (3286) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- additive manufacturing (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists.
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared.
Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions.
Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch.
Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume.
Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.