Refine
Year of publication
Institute
- INB - Institut für Nano- und Biotechnologien (533) (remove)
Has Fulltext
- no (533) (remove)
Language
- English (533) (remove)
Document Type
- Article (485)
- Conference Proceeding (33)
- Part of a Book (8)
- Doctoral Thesis (3)
- Book (2)
- Other (2)
Keywords
- frequency mixing magnetic detection (4)
- LAPS (3)
- Light-addressable potentiometric sensor (3)
- capacitive field-effect sensor (3)
- field-effect sensor (3)
- magnetic nanoparticles (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Calorimetric gas sensor (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- biosensors (2)
- gold nanoparticles (2)
- hydrogen peroxide (2)
- light-addressable potentiometric sensor (2)
- microfluidics (2)
- (Bio)degradation (1)
- Alginate beads (1)
- Bacillus atrophaeus spores (1)
- CNOT (1)
- CRISPR/Cas9 (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA biosensor (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Extracellular enzymes (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Field-effect sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Hypersecretion (1)
- Impedance spectroscopy (1)
- Lab-on-Chip (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- MOS (1)
- Marker-free mutagenesis (1)
- Multi-sensor system (1)
- Multianalyte detection (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Potentiometry (1)
- Real-time monitoring (1)
- Resonance-mode measurement (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Uracil-phosphoribosyltransferase (1)
- XOR (1)
- acetoin (1)
- actuator-sensor system (1)
- aminooctanethiol (1)
- annealing (1)
- aquaculture (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- aspergillus (1)
- bi-enzyme biosensor (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive field-effect biosensor (1)
- capacitive model (1)
- catalytic metal (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- colorization (1)
- control gate (1)
- coupled Néel–Brownian relaxation dynamics (1)
- detection of charged macromolecules (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- endospores (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- field-effect structure (1)
- filamentous fungi (1)
- frequency mixing (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- genome engineering (1)
- glucose oxidase (GOx) (1)
- heavy metals (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- impedance spectroscopy (1)
- key performance indicators (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic sensors (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- metal-oxide-semiconductor structure (1)
- micromagnetic simulation (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- multiparametric immunoassays (1)
- multiplex detection (1)
- nanobelts (1)
- nanoparticle coverage (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- penicillinase (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- polystyrene sulfonate (1)
- scanned light pulse technique (1)
- silanization (1)
- spore kill rate (1)
- sterilisation (1)
- sterility (1)
- sterilization (1)
- sterilization conditions (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- temperature (1)
- thermometry (1)
- turnip vein clearing virus (TVCV) (1)
- urease (1)
- visualization (1)
The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.
An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.
Utilizing an appropriate enzyme immobilization strategy is crucial for designing enzyme-based biosensors. Plant virus-like particles represent ideal nanoscaffolds for an extremely dense and precise immobilization of enzymes, due to their regular shape, high surface-to-volume ratio and high density of surface binding sites. In the present work, tobacco mosaic virus (TMV) particles were applied for the co-immobilization of penicillinase and urease onto the gate surface of a field-effect electrolyte-insulator-semiconductor capacitor (EISCAP) with a p-Si-SiO₂-Ta₂O₅ layer structure for the sequential detection of penicillin and urea. The TMV-assisted bi-enzyme EISCAP biosensor exhibited a high urea and penicillin sensitivity of 54 and 85 mV/dec, respectively, in the concentration range of 0.1–3 mM. For comparison, the characteristics of single-enzyme EISCAP biosensors modified with TMV particles immobilized with either penicillinase or urease were also investigated. The surface morphology of the TMV-modified Ta₂O₅-gate was analyzed by scanning electron microscopy. Additionally, the bi-enzyme EISCAP was applied to mimic an XOR (Exclusive OR) enzyme logic gate.
Transport through Redox-Active Ru-Terpyridine Complexes Integrated in Single Nanoparticle Devices
(2020)
Transition metal complexes are electrofunctional molecules due to their high conductivity and their intrinsic switching ability involving a metal-to-ligand charge transfer. Here, a method is presented to contact reliably a few to single redox-active Ru-terpyridine complexes in a CMOS compatible nanodevice and preserve their electrical functionality. Using hybrid materials from 14 nm gold nanoparticles (AuNP) and bis-{4′-[4-(mercaptophenyl)-2,2′:6′,2″-terpyridine]}-ruthenium(II) complexes a device size of 30² nm² inclusive nanoelectrodes is achieved. Moreover, this method bears the opportunity for further downscaling. The Ru-complex AuNP devices show symmetric and asymmetric current versus voltage curves with a hysteretic characteristic in two well separated conductance ranges. By theoretical approximations based on the single-channel Landauer model, the charge transport through the formed double-barrier tunnel junction is thoroughly analyzed and its sensibility to the molecule/metal contact is revealed. It can be verified that tunneling transport through the HOMO is the main transport mechanism while decoherent hopping transport is present to a minor extent.