Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1594)
- Fachbereich Wirtschaftswissenschaften (705)
- Fachbereich Elektrotechnik und Informationstechnik (637)
- Fachbereich Energietechnik (609)
- Fachbereich Chemie und Biotechnologie (603)
- INB - Institut für Nano- und Biotechnologien (541)
- Fachbereich Maschinenbau und Mechatronik (492)
- IfB - Institut für Bioengineering (450)
- Fachbereich Luft- und Raumfahrttechnik (380)
- Fachbereich Bauingenieurwesen (333)
Language
Document Type
- Article (5659) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- additive manufacturing (4)
Planar and three-dimensional (3D) interdigitated electrodes (IDE) with electrode digits separated by an insulating barrier of different heights were electrochemically characterized and compared in terms of their sensing properties. Due to the impact of the surface resistance, both types of IDE structures display a non-linear behavior in low-ionic strength solutions. The experimental data were fitted to an electrical equivalent circuit and interpreted taking into account the surface-charge-governed properties. The effect of a charged polyelectrolyte layer electrostatically assembled onto the sensor surface on the surface resistance in solutions with different KCl concentration is studied. In case of the same electrode footprint, 3D-IDEs show a larger cell constant and a higher sensitivity to molecular adsorption than that of planar IDEs. The obtained results demonstrate the potential of 3D-IDEs as a new transducer structure for a direct label-free sensing of charged molecules.
Plans for investigations of subthreshold K+ production in p+A collisions / O. W. B. Schult [u.a.]
(1995)
Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary.
Planung neuer Deponien
(1987)