Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (1620) (remove)
Language
- English (1146)
- German (472)
- Multiple languages (1)
- Spanish (1)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
- Enterprise Architecture (5)
- Gamification (5)
- Graduiertentagung (5)
- Leadership (5)
- Clusterion (4)
- Energy storage (4)
- Führung (4)
- Kanalisation (4)
- Limit analysis (4)
- Natural language processing (4)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (296)
- Fachbereich Energietechnik (259)
- Fachbereich Medizintechnik und Technomathematik (239)
- Fachbereich Maschinenbau und Mechatronik (207)
- Fachbereich Luft- und Raumfahrttechnik (203)
- Solar-Institut Jülich (167)
- IfB - Institut für Bioengineering (151)
- Fachbereich Bauingenieurwesen (137)
- Fachbereich Wirtschaftswissenschaften (68)
- ECSM European Center for Sustainable Mobility (57)
- INB - Institut für Nano- und Biotechnologien (52)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (48)
- Fachbereich Chemie und Biotechnologie (34)
- Nowum-Energy (22)
- Kommission für Forschung und Entwicklung (16)
- Fachbereich Architektur (13)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (10)
- FH Aachen (7)
- Fachbereich Gestaltung (4)
- IaAM - Institut für angewandte Automation und Mechatronik (3)
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.